Agilent 1290 Infinity UHPLC System with G4212A Diode Array Detector
3-12 month warranty
Service options & contracts available
To sell, trade-in, or service your equipment
How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us
Request Quote/ Offer
Estimate Shipping Time
Canada & U.S.: 3-5 business days
International: 5-10 business days
Tariff-Free Shipping to the U.S.!
This system includes:
- (1) Agilent 1290 G4220A Binary Pump
- (1) Agilent 1290 G4226A Infinity Sampler
- (1) Agilent 1290 G1330B Autosampler Thermostat
- (1) Agilent 1290 G1316C Thermostatted Column Compartment (TCC)
- (1) Agilent 1290 G4212A Infinity Diode Array Detector (DAD)
Agilent 1290 G4220A Binary Pump
| Type | Specifications |
|---|---|
| Hydraulic system | Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping. |
| Settable flow range | Setpoints 0.001—5 ml/min, in 0.001 ml/min increments.
Executed in 300 pl/step increments |
| Flow precision | ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min).
Based on retention time at constant room temperature. |
| Flow accuracy | ±1 % or 10 μl/min, whatever is greater.
Pumping degassed H2O at 10 MPa (100 bar) |
| Pressure operating range | Operating range up to 120 MPa (1200bar), up to 2ml/min, 80MPa (800 bar) at 5 ml/min. |
| Pressure pulsation | <1 % amplitude or < 0.5 MPa (5 bar), whatever is greater.
At 1 ml/min water |
| Compressibility compensation | Automatic, pre-defined, based on mobile phase selection. |
| Gradient formation | High pressure binary mixing. |
| Delay volume | Jet Weaver V35: <45 μl
Jet Weaver V100: <75 μl |
| Composition range | Settable range: 0 – 100 % |
| Composition precision | <0.15 % RSD, or 0.01 min SD, whatever is greater.
0.2 —5.0 ml/min; based on retention time at constant room temperature |
| Composition accuracy | ±0.35 % absolute (5 – 95 %, 0.2 – 5.0 ml/min) |
| Solvent selection valve | Default |
| Integrated degassing unit | Number of channels: 2Internal volume per channel: 1.5 mL |
| Control | Agilent ChemStation for LC (B.04.02 or above)
EZChrom Elite (3.3.2 SP1 or above) OpenLAB (3.3.2 SP3) Masshunter (B.02.01 SP1 or above) |
| Local control | Agilent Instant Pilot (G4208A) (B.02.08 or above) |
| Communications | Controller-area network (CAN), RS232C, APG remote: ready, start, stop and shutdown signals, LAN |
| Safety and maintenance | Extensive diagnostics, error detection and display (through Agilent Lab Advisor), leak detection, safe leak handling, leak output signal for shutdown of the pumping system. Low voltage in major maintenance areas. |
| GLP features | Early maintenance feedback (EMF) for continuos tracking of instrument usage in terms of purge valve switches and volume of pumped mobile phase with pre-defined and user settable limits and feedback messages. Electronic records of maintenance and errors. |
| Housing | All materials recyclable. |
Agilent 1290 G4226A Infinity Sampler
| Precision | Typically <0.25 % RSD from 5 – 20 µL
Typically <0.5 % RSD from 2 – 5 µL volume Typically <0.7 % RSD from 1 – 2 µL volume |
| Pressure range | Up to 1200 bar |
| Injection range | 0.1 – 20 µL in 0.1 µL increments |
| Sample viscosity range | 0.2 – 5 cp |
| Sample capacity | 2 x well plates (MTP) + 10 x 2 mL vials |
| Carry over | Typically <0.004 % |
| Injection cycle time | Typically <21 s using following standard
conditions:Default draw speed: 100 µL/min Default eject speed: 100 µL/min Injection volume: 5 µL |
Agilent 1290 G1330B Thermostat
| Temperature range | Settable from 4°C to 40°C in 1°C increments |
| Temperature accuracy at ambient
temperatures < 25°C and humidity < 50% |
3°C to 8°C at a setpoint of 4 °C |
| Temperature accuracy at ambient
temperatures <30°C and humidity <60% |
3°C to 9°C at a setpoint of 4°C |
Agilent 1290 G1316C Thermostatted Column Compartment
- Temperature precision specification of ± 0.05 degrees for repeatable retention times and peak areas.
- Maximum application flexibility through Peltier cooling and heating for two independent temperature zones from 10°C below ambient temperature up to 100°C.
- Low dispersion – optimized for low internal volume contribution.
- Spacious column racks provide room for three 30 cm columns or several shorter columns.
- Ultra high pressure valves for many applications such as alternating column regeneration, sample preparation and dual or multi-column selection.
- Unique pull-out and Quick Change Valve design for simplistic plumbing and valve exchange.
- Clustering of up to three 1290 Infinity TCC modules for maximum flexibility for multi-method applications such as automated method development.
- Further features include a door-open sensor, improved thermal insulation, leak funnel and capillary guide.
Agilent 1290 G4212A Infinity Diode Array Detector (DAD)
- Ultra sensitivity through revolutionary Agilent Max-Light cartridge cell with 60 mm
- optical path length (typically noise: < ± 0.6 μAU/cm).
- Universal Agilent Max-Light cartridge standard cell with 10 mm optical path length provides high sensitivity (noise: < ± 3 μAU) and lowest peak dispersion for 2.1, 3 and 4.6 mm ID columns.
- Programmable slit from 1 to 8 nm provides optimum incident light conditions for rapid optimization of sensitivity, linearity and spectral resolution.
- Multiple wavelength and full spectral detection at high sampling rate of 160 Hz, keeping pace with fastest possible analysis speed.
- More reliable and robust peak integration process due through less baseline drift.
- Full spectral detection for compound identification by spectral libraries or verification of the separation quality with peak purity analysis for ultra fast LC. Simultaneous detection of up to 8 signals for increased sensitivity and selectivity.
- Wide linear range (typically up to 2.5 AU) – for reliable, simultaneous quantification of primary compounds, by-products and impurities.
- Radio frequency identification (RFID) technology for flow cells and lamp provide new levels of data security and traceability.
- Electronic temperature control (ETC) provides maximum baseline stability and practical sensitivity under fluctuating ambient temperature and humidity conditions.
- Reference wavelength for elimination of background interference.
People Also View
Related products
-
HP Agilent 1100 Series G1376A Capillary BinPump and G1315A DAD HPLC System
Item ID: RefurbishedIn Stock
SpectraLab Scientific Inc
Established in 2003,
SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.
Our Services
Spectralab Scientific Inc. offers a variety of laboratory services to help you get started. Whether you’re setting up a new labs or developing your start up, we can help you overcome obstacles and provide turn-key solutions.
Repair Service
Parts and repairs for analytical equipment
Qualifications
IQ/OQ/PQ centered on compliance and data integrity
Service Contracts
Protect your lab and minimize downtime
Warranty
Up to 5 years warranty on most of the equipment
Installation & Training
Hassle-free setup & training from our professionals
Maintenance
Yearly PM to ensure peak performance