PerkinElmer 200 Series Fluorescence Detector (FLD)
Item ID:
Manufacturer
Condition
3-12 month warranty
Service options & contracts available
To sell, trade-in, or service your equipment
How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us
$4350 USD
Estimate Shipping Time
Canada & U.S.: 3-5 business days
International: 5-10 business days
Tariff-Free Shipping to the U.S.!
This refurbished Perkin Elmer 200 Series Fluorescence Detector (FLD) is in great condition. It has been tested at SpectraLab Scientific.
A 90 day warranty is included.
| Specification | |
| Optical system | Ratio photometry; intensity of transmitted beam is monitored. |
| Light source |
Xe lamp (150 W) Hg lamp (for checking wavelength) |
| Measuring wavelength range Excitation wavelength | 200 to 850 nm/Zero order |
| Measuring wavelength range emission wavelength |
250 to 900 nm/Zero order Photomultiplier must be changed at emission wavelength greater than 731 nm |
| Spectral bandwidth excitation side | 15 nm |
| Spectral bandwidth emission side |
15 nm, 30 nm (variable) * With this instrument, spectrum bandwidth is defined by half-value width. Therefore, in order to separate a spectrum completely, a wavelength interval of 30 nm or more is required |
| Wavelength setting | By communication (E-line) or keyboard |
| Wavelength accuracy | ±3 nm |
| Wavelength repeatability | ±0.5 nm |
| Recorder output (option) | 10 mV full-scale; full scale range 1 to 1000 settable in increments of 1 |
| Processor output (option) | 1 V full-scale -40 to 1000 mV |
| Response | Changeable in 7 steps corresponding to time constants of 0.05/0.1/0.5/1.0/2.0/4.0/8.0 seconds |
| Sensitivity |
a. With emission-side spectral bandwidth set at 15 nm S/N ratio for Raman peak of water 700 or more (Baseline method) S/N ratio for Raman peak of water 525 or more (Tangent method) b. With emission-side spectral bandwidth set at 30 nm S/N ratio for Raman peak of water 900 or more (Baseline method) Wavelength: 350 nm, Time constant: 2.0 s |
| Auto Zero range | 0 to 1000 |
| Offset range | 0 to 1000 (settable in steps of 1) |
| Time program |
Number of programs 9 Settable time Up to 600 minutes increments of 0.1 minute Number of steps storable 100 steps for a total of 9 files Programmable parameters Measurement wavelength (Ex and Em) Baseline processing PMT gain |
| External Output terminals |
Analog output for processor 1 V full scale Analog output for recorder 10 mV full scale |
| Flow cell capacity | Standard cell 12 μL (irradiated capacity) |
| Flow cell withstand pressure | 1.0 MPa |
| Operating temperature range | 4 to 35 °C (non-condensing) |
| Operating humidity range | 25 to 85% RH (non-condensing) |
People Also View
Related products
-
PerkinElmer 200 Series HPLC System with 785A UV/Vis Detector
Item ID: RefurbishedIn StockPrice:$7500 USD
SpectraLab Scientific Inc
Established in 2003,
SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.
Our Services
Spectralab Scientific Inc. offers a variety of laboratory services to help you get started. Whether you’re setting up a new labs or developing your start up, we can help you overcome obstacles and provide turn-key solutions.
Repair Service
Parts and repairs for analytical equipment
Qualifications
IQ/OQ/PQ centered on compliance and data integrity
Service Contracts
Protect your lab and minimize downtime
Warranty
Up to 5 years warranty on most of the equipment
Installation & Training
Hassle-free setup & training from our professionals
Maintenance
Yearly PM to ensure peak performance