Waters e2695 Alliance HPLC System with 2414 RID
Item ID:
Manufacturer
Condition
3-12 month warranty
Service options & contracts available
To sell, trade-in, or service your equipment
How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us
Request Quote/ Offer
Estimate Shipping Time
Canada & U.S.: 3-5 business days
International: 5-10 business days
Tariff-Free Shipping to the U.S.!
The Waters Alliance HPLC Systems are recognized as the industry standard in performance and reliability. Whether you are expanding your laboratory capacity, have increasingly challenging assays, or have greater throughput requirements, the Alliance HPLC System has many optional accessories designed to extend the system’s capabilities to fit your changing business needs.
System includes:
- Waters e2695 Separations Module HPLC system (with built-in autosampler, quaternary pump, degasser, and sample heater/cooler)
- Waters 2414 RI Detector
- Column heater/ cooler
- LAC/E32 Acquisition Server (optional)
- Empower 3 data system
Two sets are available in stock. We have other detectors, accessories and components to mix and match to fit your needs.
Specifications:
| Type | Specifications |
|---|---|
| Number of sample vials | 120 vials configured in 5 carousels of 24 vials each |
| Number of sample injections | 1 to 99 injections per sample vial |
| Sample delivery precision | Typically < 0.5% RSD, 5 to 80 μL. (Degassed methanol/water 60:40 Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 254 nm.) |
| Injector needle wash | Integral, active, programmable |
| Sample carryover | < 0.01% (based on the following chromatographic conditions):
• Column – XBridge C18, 4.6 × 50 mm, 3.5 μm • Mobile Phase – 70% Water/30% Methanol • Needle Wash – 100% Methanol • Challenge Sample – 4.0 mg/mL caffeine (in mobile phase) • Carryover Standard – 0.4 mg/mL caffeine (in mobile phase) • Injection Volume (all) – 5.0 μL |
| Injection accuracy | ±1 μL (±2%), 50 μL, N = 6. Sample is degassed water, analytical solvent is degassed methanol.Standard sample vial2 mL |
| Sample temperature control (optional) | Ambient minus 25 °C or 4 °C (whichever is greater) to 40 °C, in 1 °C increments
• ± 3 °C temperature accuracy • 60 minute time limit from lab ambient to heating setpoint • 90 minute time limit from lab ambient to cooling setpoint |
| Advanced operations | Stat runs, auto additions, auto standards |
| Injection volume range | 0.1 to 100 μL, standard; 0.1 to 2000 μL, with optional sample loop |
| Injector linearity | > 0.999 coefficient of deviation (1 to 100 μL) |
People Also View
Related products
-
We may customize your HPLC system upon your specific chromatography needs.
Item ID: RefurbishedIn Stock -
Waters HPLC with 600 Quat Pump, 717 Plus Autosampler, 486 Tunable Wavelength Detector and Degasser
Item ID: RefurbishedIn Stock -
Waters CapLC System with capillary Gradient Pump, Capillary PDA and SPH Autosampler(Capillary)
Item ID: RefurbishedSold Out
SpectraLab Scientific Inc
Established in 2003,
SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.
Our Services
Spectralab Scientific Inc. offers a variety of laboratory services to help you get started. Whether you’re setting up a new labs or developing your start up, we can help you overcome obstacles and provide turn-key solutions.
Repair Service
Parts and repairs for analytical equipment
Qualifications
IQ/OQ/PQ centered on compliance and data integrity
Service Contracts
Protect your lab and minimize downtime
Warranty
Up to 5 years warranty on most of the equipment
Installation & Training
Hassle-free setup & training from our professionals
Maintenance
Yearly PM to ensure peak performance