Performance Specifications Agilent 1260 Infinity Fluorescence Detector (G1321C)

Type Specification Comments
Detection type One signal wavelength (excitation and emission) Programmable single

wavelength (excitation

and emission)

fluorescence detector

Performance specifications Single wavelength operation:

• RAMAN (H2O) > 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell

• RAMAN (H2O) > 3000 (noise reference measured at dark value)

Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell

see note below this table

see Service Manual for details

Light source Xenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h
Pulse frequency 296 Hz for single signal mode

74 Hz for economy mode

Maximum data rate 74 Hz
Excitation monochromator Range: settable 200 nm – 1200 nm and zero-order

Bandwidth: 20 nm (fixed)

Monochromator: concave holographic grating, F/1.6, blaze: 300 nm

Emission monochromator Range: settable 200 nm – 1200 nm and zero-order

Bandwidth: 20 nm (fixed)

Monochromator: concave holographic grating, F/1.6, blaze: 400 nm

Reference system in-line excitation measurement
Timetable programing up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters
Wavelength characteristic Repeatability +/- 0.2 nm

Accuracy +/- 3 nm setting

Flow cells Standard: 8 µL volume and 20 bar (2 MPa) pressure maximum, fused silica block

Optional:

• Fluorescence cuvette for offline spectroscopic measurements with 1 mL syringe, 8 µL volume

• Bio-inert: 8 µL volume and 20 bar (2 MPa) pressure maximum, (pH 1–12)

• Micro: 4 µL volume and 20 bar (2 MPa) pressure maximum

Control and data evaluation Agilent ChemStation for LC, Agilent Instant Pilot G4208A with limited spectral data analysis and printing of spectra
Analog outputs Recorder/integrator: 100 mV or 1 V,

output range > 100 LU, two outputs

100 LU is the recommended range, see “FLD Scaling Range and Operating Conditions”
Communications Controller-area network (CAN), RS-232C, LAN, APG

Remote: ready, start, stop and shut-down signals

Safety and maintenance Extensive support for troubleshooting and maintenance is provided by the Instant Pilot, Agilent Lab Advisor, and the Chromatography Data System.

Safety-related features are leak detection, safe leak handling, leak output signal for shutdown of pumping system, and low voltages in major maintenance areas.

GLP features Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy, using the Raman band of water.
Housing All materials recyclable.
Environment 0 – 40 °C constant temperature at <95 % humidity (non-condensing)
Dimensions 140 mm x 345 mm x 435 mm

(5.5 x 13.5 x 17 inches)

(height x width x depth)

Weight 11.5 kg (25.5 lbs)

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare