Agilent 1290 Infinity UHPLC System with G1314F Variable Wavelength Detector
3-12 month warranty
Service options & contracts available
To sell, trade-in, or service your equipment
How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us
Request Quote/ Offer
Estimate Shipping Time
Canada & U.S.: 3-5 business days
International: 5-10 business days
Tariff-Free Shipping to the U.S.!
This system includes:
- (1) Agilent 1290 G4220A Binary Pump
- (1) Agilent 1260 G4226A Autosampler
- (1) Agilent 1290 G1316C Thermostatted Column Compartment (TCC)
- (1) Agilent 1260 G1314F Variable Wavelength Detector (VWD)
Agilent 1290 G4220A Binary Pump
| Type | Specifications |
|---|---|
| Hydraulic system | Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping. |
| Settable flow range | Setpoints 0.001—5 ml/min, in 0.001 ml/min increments.
Executed in 300 pl/step increments |
| Flow precision | ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min).
Based on retention time at constant room temperature. |
| Flow accuracy | ±1 % or 10 μl/min, whatever is greater.
Pumping degassed H2O at 10 MPa (100 bar) |
| Pressure operating range | Operating range up to 120 MPa (1200bar), up to 2ml/min, 80MPa (800 bar) at 5 ml/min. |
| Pressure pulsation | <1 % amplitude or < 0.5 MPa (5 bar), whatever is greater.
At 1 ml/min water |
| Compressibility compensation | Automatic, pre-defined, based on mobile phase selection. |
| Gradient formation | High pressure binary mixing. |
| Delay volume | Jet Weaver V35: <45 μl
Jet Weaver V100: <75 μl |
| Composition range | Settable range: 0 – 100 % |
| Composition precision | <0.15 % RSD, or 0.01 min SD, whatever is greater.
0.2 —5.0 ml/min; based on retention time at constant room temperature |
| Composition accuracy | ±0.35 % absolute (5 – 95 %, 0.2 – 5.0 ml/min) |
| Solvent selection valve | Default |
| Integrated degassing unit | Number of channels: 2Internal volume per channel: 1.5 mL |
| Control | Agilent ChemStation for LC (B.04.02 or above)
EZChrom Elite (3.3.2 SP1 or above) OpenLAB (3.3.2 SP3) Masshunter (B.02.01 SP1 or above) |
| Local control | Agilent Instant Pilot (G4208A) (B.02.08 or above) |
| Communications | Controller-area network (CAN), RS232C, APG remote: ready, start, stop and shutdown signals, LAN |
| Safety and maintenance | Extensive diagnostics, error detection and display (through Agilent Lab Advisor), leak detection, safe leak handling, leak output signal for shutdown of the pumping system. Low voltage in major maintenance areas. |
| GLP features | Early maintenance feedback (EMF) for continuos tracking of instrument usage in terms of purge valve switches and volume of pumped mobile phase with pre-defined and user settable limits and feedback messages. Electronic records of maintenance and errors. |
| Housing | All materials recyclable. |
Agilent 1260 G7167A Multisampler
- Sample drawers are available in three heights to accommodate any combination of sample containers for maximum flexibility
- Shallow microplate drawers take a maximum load of 16 microplates and up to 6,144 samples for unmatched sample capacity
- Robotics move microplates and other sample containers from sample hotel to central workspace for seamless automation during sample processing steps and injections
- Dual-needle setup enables reduction of injection cycle times to mere seconds, virtually eliminating conventional wait times
- Dual-needle injection paths can be individually optimized for enhanced injection flexibility
- Multiwash capability flushes the outside surfaces of the injection needle outside with three solvents and uses seat backflush procedures to reduce carryover to less than 9 ppm
- Integrated sample thermostat, available as option or upgrade, provides cooling and heating from 4 to 40 °C
- Lights on each drawer indicate loading status, current activity, and accessibility for instant information
Agilent 1290 G1316C Thermostatted Column Compartment
- Temperature precision specification of ± 0.05 degrees for repeatable retention times and peak areas.
- Maximum application flexibility through Peltier cooling and heating for two independent temperature zones from 10°C below ambient temperature up to 100°C.
- Low dispersion – optimized for low internal volume contribution.
- Spacious column racks provide room for three 30 cm columns or several shorter columns.
- Ultra high pressure valves for many applications such as alternating column regeneration, sample preparation and dual or multi-column selection.
- Unique pull-out and Quick Change Valve design for simplistic plumbing and valve exchange.
- Clustering of up to three 1290 Infinity TCC modules for maximum flexibility for multi-method applications such as automated method development.
- Further features include a door-open sensor, improved thermal insulation, leak funnel and capillary guide.
Agilent 1260 G1314F Variable Wavelength Detector (VWD)
- Robust quantification of trace level components: Lowest baseline noise and drift results in lowest detection limits
- More analyte information per run with dual-wavelength capabilities
- High-resolution gain in fast LC at up to 120 Hz data acquisition rate
- Wide linear range (>2.5 AU upper limit) for reliable, simultaneous quantification of primary compounds, by-products, and impurities
- Efficient temperature control: Next-generation electronic temperature control (ETC) provides maximum baseline stability and practical sensitivity under fluctuating ambient temperature and humidity conditions
- Automatic wavelength verification provided using built-in holmium oxide filter
- Fast wavelength optimization with stop-flow wavelength scanning
- New levels of data traceability with radio frequency identification (RFID) technology for flow cells and lamps
- Maximum flexibility, compatibility, and investment protection with a range of eight analytical and preparative flow cells
- Continuous tracking of instrument usage: Early maintenance feedback (EMF) continuously tracks lamp burn time with user-defined limits and message types
- Extensive analytics, error detection, and displays using Agilent Lab Advisor software
People Also View
Related products
-
HP Agilent 1100 Radio-HPLC system with IN/US Beta-Ram Radio-HPLC Detector
Item ID: RefurbishedIn Stock -
HP 1050 Quat Pump, HP 1050 VWD and HP 1050 Thermostatted column compartment
Item ID: RefurbishedIn StockPrice:$4300 USD
SpectraLab Scientific Inc
Established in 2003,
SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.
Our Services
Spectralab Scientific Inc. offers a variety of laboratory services to help you get started. Whether you’re setting up a new labs or developing your start up, we can help you overcome obstacles and provide turn-key solutions.
Repair Service
Parts and repairs for analytical equipment
Qualifications
IQ/OQ/PQ centered on compliance and data integrity
Service Contracts
Protect your lab and minimize downtime
Warranty
Up to 5 years warranty on most of the equipment
Installation & Training
Hassle-free setup & training from our professionals
Maintenance
Yearly PM to ensure peak performance









