info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688

Agilent 5977B Inert Plus GC-MSD with 7890B GC and 7697A Headspace Autosampler

Item ID:

AGCMS-7890B-5977B

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

This system includes:

  • (1) 7890B Gas Chromatograph (G3440BR)
  • (1) 7697A Headspace Sampler, 111-vial (G4557AR)
  • (1) G1888A/7697A Headspace Control Software (G5350AA)
  • (1) 5977B Inert Plus MSD (G7077B)
  • Rough pump
  • PC with data

Agilent GCMS 7890B Gas Chromatograph

  • Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
  • Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
  • Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
  • Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
  • Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
  • Carrier Gas Options: Helium Conservation Module, Hydrogen Sensors and Alternate Carrier Gas Solutions dramatically reduce the amount of helium used to offer flexibility in your laboratory
  • Large Valve Oven (LVO) allows for the combination of multiple methods and simplified maintenance
  • Multimode inlet (MMI) serves as a programmable temperature vaporizing injector with flexible capabilities
  • Agilent Inert Flow Path provides increased sensitivity for active compounds, from injection to detection
  • Low Thermal Mass (LTM) modules, up to 4 installed and operating, increase sample throughput with rapid column heating and cooling

5977B Inert Plus MSD

  • Improve sensitivity (10x greater) with detection limits as low as 1.5 fg IDL, bringing yesterday’s triple-quadrupole limits of detection into today’s single quadrupole laboratory
  • Reduce time spent on sample prep and maintenance, while meeting your current sensitivity requirements, with just 1/10 of the original sample volume
  • Minimize operating and shipping costs by storing, prepping, and disposing of 10x less material
  • Benefit from eco-friendly features, such as Sleep/Wake modes, and conserve electricity and other resources like carrier gas
  • Greatly reduce or even eliminate the need for manual source cleaning with the JetClean self-cleaning ion source
  • The built-in intelligence of the 8890 GC drives productivity with diagnostics, monitoring, and simplified access to powerful operations through the integrated touchscreen and browser interface
  • Inert Flow Path provides improved performance for sensitive analytes at low levels, extending the range of quantitation and detection
  • Simplify method development, from instrument settings to data analysis and reporting with MassHunter Software

7697A Headspace Sampler

  • The 7697A Headspace Sampler 12 Vial Capacity configuration is perfect for academic labs and those with small sample loads
  • Standard 111 sample configuration with 3 priority samples
  • Exchangeable trays during a sequence for increased sample capacity
  • Hydrogen carrier and auto Sleep/Wake modes conserve valuable laboratory resources
  • Software control through Agilent OpenLAB CDS software and Agilent MassHunter software
  • Software control with Waters Empower 2 software and Waters Empower™ 3 software
  • Independent control of vial pressurization and column head pressure provides increased precision by ensuring no back pressure during sample transfer
  • Automatic vial leak test checks each vial during pressurization – without time consuming calibration – to ensure that every sample is properly capped
  • Sample Bar Code Reader with data transfer capabilities allows you to track samples before they enter the oven
  • Multiple headspace concentrations (MHC) with up to 100 extractions per GC start allows for more complete sampling and increased sensitivity
  • Multiple headspace extractions (MHE) with up to 100 extractions per vial
  • Supports 10 mL, 20 mL, or 22 mL vials without an adapter
  • Method development software transfers methods from any headspace system or quickly designs a method from scratch using just a few known parameters
  • Samples depressurize before returning to tray

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare