info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688

Agilent 7890B GC with Agilent 7010 QQQ GC/MS and 7693A Autosampler

Item ID:

A7890B-AG7010A-G4514

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

Out of stock

This Set includes:

  • (1) Agilent 7890B GC
  • (1) Agilent 7010 (G7012A) Triple Quadrupole Mass Spectrometer
  • (1) Agilent G4513A Autoinjector
  • (1) Agilent G4514A 7693A Autosampler with 150 position Tray
  • (1) Edwards Rotary Vane Pump RV5
  • (1) PC with data

Agilent 7890B GC

  • Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
  • Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
  • Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
  • Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
  • Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
  • Carrier Gas Options: Helium Conservation Module, Hydrogen Sensors and Alternate Carrier Gas Solutions dramatically reduce the amount of helium used to offer flexibility in your laboratory
  • Large Valve Oven (LVO) allows for the combination of multiple methods and simplified maintenance
  • Multimode inlet (MMI) serves as a programmable temperature vaporizing injector with flexible capabilities
  • Agilent Inert Flow Path provides increased sensitivity for active compounds, from injection to detection
  • Low Thermal Mass (LTM) modules, up to 4 installed and operating, increase sample throughput with rapid column heating and cooling

Agilent 7010 (G7012A) QQQ

  • New High-Efficiency EI Ion Source
    • This all-new EI source delivers astonishingly low detection limits. Demonstrated installation specification, with 2 fg OFN injected: IDL ≤ 0.5fg.
  • Heated Gold Quadrupoles, Triple-Axis HED-EM Detector and Fast Venting
    • Enhance mass spec performance by reducing common contaminants, neutral noise and cool down time.
  • Integrated GC/MS system features and Early Maintenance Feedback (EMF)
    • Align and monitor GC/MS operation to maximize uptime and aid with planned maintenance.

Agilent G413A Autoinjector

  • Dual simultaneous injection saves time by doubling sample throughput
  • Fast injection technology minimizes needle discrimination and sample degradation
  • Perform single-stroke injection of up to 50 µL using a 100 µL syringe; multiple injections are possible depending on your needs
  • Eliminate analyst-to-analyst variability and reduce rework using powerful sample preparation capabilities, including dilution, internal standard addition, heating, mixing, and solvent addition
  • Modular design allows the flexibility to easily move the sampler from GC to GC or start with a single injector and add on to the system as needed

Edwards Rotary Vane Pump RV5

Displacement
  50Hz 5.8 m3h-1 / 3.4 ft3min-1
  60Hz 7.0 m3h-1 / 4.1 ft3min-1
Speed (Pneurop 6602)
  50Hz 5.1 m3h-1 / 3.0 ft3min-1
  60Hz 6.2 m3h-1 / 3.7 ft3min-1
Ultimate pressure 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
Ultimate pressure GB I 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
Ultimate pressure GB II 1.0 x 10-1 mbar / 7.5 x 10-2 Torr
Ultimate Pressure with Fomblin® 2.0 x 10-2 mbar / 1.5 x 10-2 Torr
Max inlet pressure for water vapour 50 mbar / 38 Torr
Max water vapour pumping rate – GB I 60 gh-1
Max water vapour pumping rate – GB II 220 gh-1
Max allowed outlet pressure 0.2 bar gauge / 2.8 psig
Max allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig
Motor power 50/60Hz 450 / 550W
Power connector 1-ph IEC EN60320 C13
Nominal rotation speed 50/60Hz 1500 / 1800rpm
Weight (without oil) 25 kg / 55 lb
Oil capacity min/max 0.42/0.7 litres
Recommended oil Ultragrade 19
Inlet flange NW25
Exhaust flange NW25
Noise level 48 dB(A) @ 50 Hz
Operating temperature range 12 – 40 °C

 

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare