Brand new Thermo Scientific ISQ LT Single Quadrupole Mass Spectrometer

Item ID:

TSISQ-LTSQ-MS

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

Out of stock

This system includes:

  • (1) Thermo Scientific ISQ LT Single Quadrupole Mass Spectrometer
  • (1) Thermo Scientific Direct Probe Controller
  • (1) Thermo Scientific GC Column
  • (1) Edwards Rotary Pump
  • PC with software

Thermo Scientific ISQ LT Single Quadrupole Mass Spectrometer

Mass Range 1.2 to 1100 U with Unit Mass Resolution
Detectors DynaMax XR
EI Full Scan Installation Specification 1 µL of 1 pg/µL Octafluoronaphthalene (OFN) Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U:600:1 Using Helium as Carrier Gas
Electron Energy Adjustable From 0 to 150 eV
Emission Current Up to 350 µA
Mass Filter Dual-Stage Mass Filter with Off-Axis Ion Guide and Solid, Homogeneous Non-Coated Quadrupole Rods
Modes Standard: Electron Ionization (EI), with Full Scan, SIM, and Sequential Full Scan/SIM; Optional: Chemical Ionization, Including PCI, NCI, PPINICI and EI/CI Combination
Negative Chemical Ionization Installation Spec 2 µL of 100 fg/µL of OFN Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U Using Methane Reagent Gas: 600:1 Using Helium as Carrier Gas
Pumping Systems Standard Capacity (>60 L/s) or High-Capacity (>230 L/s), or Extended Capacity (300 L/s) Turbomolecular Pump with 3.3 m3/h Mechanical Pump; Optional Oil-Free Scroll Pump
Reagent Gas Software-Switchable Dual Reagent Gas with Digital Flow Control
Scanning Capabilities Scan Rate: Up to 20,000 U/Sec; Scan Cycles: 97 Scans/Sec to Disc When Scanning Across 125 U
Source Type ExtractaBrite EI Source, with Repeller, Source Lenses, RF Lens and Dual Filaments in All Ionization Modes
Vacuum Probe Interlock Vacuum Probe Interlock to Remove Entire Source or Change Ionization Modes Without Venting
Item Description ISQ Single Quadrupole Mass Spectrometer

Thermo Scientific Direct Probe Controller

The Direct Probe Controller (DPC) is used to communicate information from a sample probe (DIP or DEP) to the mass spectrometer. The DPC also allows you to enter heating and data acquisition parameters to the mass spectrometer. Direct probe systems allow rapid sample screening for any application that do not require a gas chromatograph (GC) column separation. Another advantage to using a DIP or a DEP is to have a wide range of samples to volatilize directly into the ion source.

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare