info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688

Dionex Ics-3000 Ion Chromatography System

Item ID:

Dionex-04-0690

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

Features
The ICS-3000 Ion Chromatography System provides an impressive combination of increased productivity, expanded capabilities, and improved performance. Innovations in all modules provide up to an order of magnitude improvement in performance—the foundation of the system. Modular versatility, functional integration, and superior performance culminate in the most advanced ion chromatography system on the market.

  • Modular design allows versatility in configuring a wide variety of applications
  • Performance improvements up to an order of magnitude in flow rate accuracy, eluent generator electronics stability, and conductivity cell temperature control increase retention time reproducibility, baseline stability, and sensitivity
  • New hydroxide and carbonate Reagent-Free Ion Chromatography (RFIC) consumables offer the greatest flexibility of any RFIC system
  • Dual-system capability (within the same footprint) maximizes throughput
  • Integrated DC Detector/ Chromatography module with precisely controlledtemperature zones maintains baseline stability and increases applicationflexibility
  • AM Automation Manager simplifies and automates complex applications including sample preparation, preconcentration, matrix elimination andpost column reagent addition
  • New innovative ED Electrochemical Detector capabilities improve andexpand applications: multiwaveforms in a single run; post-run 3-D data processing; new cell design
  • Innovative touchscreen TabletStation, mounted on a movable arm, unifies and simplifies system control and operation

This Dionex Ics-3000 Ion Chromatography System includes:

  • Dionex ICS-3000 Dual Pump (DP)
  • Dionex ICS-3000 Eluent Generator (EG)
  • Dionex ICS-3000 Detector/Chromatography Module (DC)
  • Dionex AS-40 Autosampler

This refurbished Dionex Ics-3000 Ion Chromatography System is in good condition.

Specifications:

 
Feature
 
 
Isocratic Pump
 
 
Gradient Pump
 
 
Pump
 
 
Dual-piston (in series), variable speed, 80 μL per revolution
 
 
Dual-piston (in series), variable speed, 80 μL per revolution
 
 
Flow Rate Range
 
 
0.001 to 10.0 mL/min in increments of 0.001 mL/min
 
 
0.001 to 10.0 mL/min in increments of 0.001 mL/min
 
 
Flow Rate Accuracy
 
and Reproducibility
 
 
±0.1% at 1.0 mL/min (typical)
 
 
±0.1% at 1.0 mL/min (typical)
 
 
Operating Pressure
 
 
0.1 to 35 MPa (15 to 5000 psi)
 
 
0.1 to 35 MPa (15 to 5000 psi)
 
 
Pressure Ripple
 
 
1% (typical)
 
 
1% (typical)
 
 
Gradient Proportioning Accuracy and Reproducibility
 
 
Not applicable
 
 
±0.5% at 2.0 mL/min (typical)
 
 
Number of Eluents
 
 
One
 
 
Four
 
 
Gradient Mixer Delay Volume
 
 
Not applicable
 
 
GM-3: <500 μL, 3 to 9 mm ID columns
 
GM-4: <290 μL, 2 mm ID columns
 
 
High Pressure Limit
 
 
0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously
 
 
0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously
 
 
Low Pressure Limit
 
 
0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi)
 
 
0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi)
 
 
Vacuum Degassing
 
Module
 
 
Built-in single-channel degas chamber (with degassing membrances) with internal volume of 670 µL and dual-stage diaphragm vacuum pump
 
 
Built-in four-channel degas chamber (with degassing membranes) with internal volume of 670 μL per channel and dual-stage diaphragm vacuum pump
 

 

 
Eluent Generator
 
 

 
 
Operating
 
Temperature
 
 
4 to 40 °C (40 to 104 °F)
 
 
Operating
 
Humidity
 
 
5% to 95% relative humidity, noncondensing
 
 
Operating Pressure
 
 
Minimum: 14 MPa (2000 psi)
 
Maximum: 21 MPa (3000 psi)
 
 
Dimensions
 
 
Height: 40.6 cm (16 in)
 
Width: 22 cm (8.75 in)
 
Depth: 55.9 cm (22 in)
 
Minimum required clearance behind the EG: 5 cm (2 in)
 
 
Weight
 
 
18 kg (40 lb)
 

 

 
Conductivity Detector
 
 

 
 
Electronics
 
 
Microprocessor-controlled digital signal processing
 
 
Detection Types
 
 
Single- or dual-conductivity detection. Dual-detection can be controlled either simultaneously or independently
 
 
Cell Drive
 
 
8 kHz square wave
 
 
Linearity
 
 
1% at 1000 µS
 
 
Resolution
 
 
0.10 nS
 
 
Signal Sampling Rate
 
 
Maximum of 100 Hz
 
 
Electronic Noise, Dry
 
 
S/N ratio = 200,000:1 (Example: 1000 µS:5 nS)
 
 
Electronic Noise, Wet
 
 
At 23 µS, noise <0.2 nS
 
At 1 µS, noise <0.1 nS
 
 
Filter
 
 
Rise times from 0 to 10 s
 
 
Temperature Compensation
 
 
Factory set at 1.7% per °C; programmable from 0.0 to 3.0% per °C
 
 
Cell Body
 
 
PEEK
 
 
Cell Electrodes
 
 
Passivated 316 stainless steel
 
 
Active Volume of Cell
 
 
< 1.0 µL
 
 
Cell Operating Temperature
 
 
5 ºC above the DC detector compartment temperature; maximum of 60 ºC
 
 
Cell Maximum Operating Pressure
 
 
3 MPa (500 psi)
 
 
Signal Gain Ranges
 
 
0 to 180 µS, 0 to 1000 µS, and 0 to 15,000 µS
 
 
Optional Analog Output Full-Scale Ranges
 
 
Three separate ranges from 0 to 15,000 µS
 
 
Electrochemical Detector
 
 

 
 
Electronics
 
 
Microprocessor-controlled digital signal processing
 
 
Detection Types
 
 
Single- or dual-electrochemical detection. Dual-detection can be controlled either simultaneously or independently.
 
 
Noise
 
 
< 1 pA (DC Amperometry)
 
10 pC (Integrated Amperometry)
 
 
Cell Drive Potential Settings
 
 
-2.00 to 2.00 V in 0.001 V increments
 
 
Optional Analog Output Range
 
 
50 pC to 200 μC (Integrated Amperometry)
5 pA to 74 μA (DC Amperometry)
 
 
Cell Working Electrode
 
 
Disposable gold, silver, or platinum
 
Non-disposable platinum, gold, silver, or glassy carbon
 
 
Cell Counter
 
Electrode
 
 
Titanium
 
 
Cell Reference Electrode
 
 
pH-Ag/AgCl combination
 
 
Wetted Materials
 
 
PEEK, titanium, Kel-F, polyetherimide, EPR, glass, high density
 
polyethylene (HDPE), ULTEM, Teflon working electrode
 
materials
 
 
Cell Volume at Working Electrode
 
 
< 0.5 µL
 
 
Cell Maximum Operating Pressure
 
 
0.7 MPa (100 psi)
 

 

 
Thermal Compartment
 
 

 
 
Temperature Control Range
 
 
5 to 85 °C in 0.1 °C increments (41 to 185 °F in 0.18 °F increments); thermo-electric control
 
 
Temperature Accuracy
 
 
±0.5 °C (0.9 °F)
 
 
Temperature Stability
 
 
±0.1 °C (0.18 °F)
 
 
Temperature Precision
 
 
±0.1 °C (0.18 °F)
 
 
Column Capacity
 
 
Up to 3 columns; maximum length of 30 cm (11.8 in)
 
 
Heat-up Time
 
 
< 20 min from 20 to 50 °C (68 to 122 °F)
 
 
Cooldown Time
 
 
< 20 min from 50 to 20 °C (122 to 68 °F)
 
 
Control
 
 
Provided by Chromeleon or Chromeleon Xpress software; the TC and the host computer are connected through USB (Universal Serial Bus)
 
 
I/O Interfaces
 
 
2 digital inputs, 2 programmable relay outputs
 
 
Injection Valve
 
 
Electrically-activated Rheodyne TitanHP valve: 2-position, 6-port
 
or 2-position, 10-port (up to two valves can be installed)
 
 
Safety Features
 
 
Humidity sensor and gas sensor
Temperature control and temperature sensors

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare