info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688

Dionex ICS-3000 System with Autosampler, Dual Pump, Eluent Generator, Detector, and Eluent Organizer

Item ID:

Dionex-04-0600

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

Features:

  • Modular design allows versatility in configuring a wide variety of applications
  • performance improvements up to an order of magnitude in flow rate accuracy
  • electronics stability and conductivity cell temperature control increase retention time reproducibility, baseline stability, and sensitivity
  • New hydroxide and carbonate Reagent-Free Ion chromatography consumables offer the greatest flexibility of any RFIC system
  • Dual-system capability (within the same foot print) maximizes throughput
  • Integrated DC Detector/chromatography module with precisely controlled temperature zones maintains baseline stability and increases application flexibility
  • AM Automation Manager simplifies and automates complex applications including sample preparation, preconcentration, matrix elimination and post column reagent addition
  • New innovative ED Electrochemical Detector capabilities improve and expand application:multi-waveforms in a single run; post-run 3-D data processing: new cell design
  • Innovative touchscreen Tablet Station, mounted on a movable arm, unifies and simplifies system control and operation

This Dionex ICS 3000 Ion Chromatography System includes:

  • Single or Dual Pump (DP/ SP)
  • Eluent Generator (EG)
  • Eulent Organizer
  • Detector/Chromatography Module (DC)
  • AS Autosampler

This is a sample set. We have many more components, so please feel free to contact us if you have any requests. A 90 day warranty is included.
We look forward to hearing from you in the future.

Specifications:

Feature Isocratic Pump Gradient Pump
Pump Dual-piston (in series),
variable speed, 80 μL per
revolution
Dual-piston (in series),
variable speed, 80 μL per
revolution
Flow Rate Range 0.001 to 10.0 mL/min in
increments of 0.001 mL/min
0.001 to 10.0 mL/min in
increments of 0.001 mL/min
Flow Rate Accuracy
and Reproducibility
±0.1% at 1.0 mL/min
(typical)
±0.1% at 1.0 mL/min
(typical)
Operating Pressure 0.1 to 35 MPa  (15 to 5000 psi) 0.1 to 35 MPa  (15 to 5000 psi)
Pressure Ripple 1% (typical) 1% (typical)
Gradient Proportioning Accuracy and Reproducibility Not applicable ±0.5% at 2.0 mL/min
(typical)
Number of Eluents One Four
Gradient Mixer Delay Volume Not applicable GM-3: <500 μL, 3 to 9 mm
ID columns
GM-4: <290 μL, 2 mm ID
columns
High Pressure Limit 0 to 35 MPa (0 to 5000 psi) in
increments of 0.1 MPa
(14 psi); trips instantaneously
0 to 35 MPa (0 to 5000 psi) in
increments of 0.1 MPa
(14 psi); trips instantaneously
Low Pressure Limit 0 to 34 MPa (0 to 4900 psi) in
increments of 0.1 MPa
(14 psi)
0 to 34 MPa (0 to 4900 psi) in
increments of 0.1 MPa
(14 psi)
Vacuum Degassing
Module
Built-in single-channel degas chamber (with degassing membrances) with internal volume of 670 µL and dual-stage diaphragm vacuum pump Built-in four-channel degas
chamber (with degassing
membranes) with internal
volume of 670 μL per
channel and dual-stage
diaphragm vacuum pump

 

Eluent Generator    
Operating
Temperature
4 to 40 °C (40 to 104 °F)
Operating
Humidity
5% to 95% relative humidity, noncondensing
Operating Pressure Minimum: 14 MPa (2000 psi)
Maximum: 21 MPa (3000 psi)
Dimensions Height: 40.6 cm (16 in)
Width: 22 cm (8.75 in)
Depth: 55.9 cm (22 in)
Minimum required clearance behind the EG: 5 cm (2 in)
Weight 18 kg (40 lb)

Conductivity Detector  
Electronics Microprocessor-controlled digital signal processing
Detection Types Single- or dual-conductivity detection. Dual-detection can be controlled either simultaneously or independently
Cell Drive 8 kHz square wave
Linearity 1% at 1000 µS
Resolution 0.10 nS
Signal Sampling Rate Maximum of 100 Hz
Electronic Noise, Dry S/N ratio = 200,000:1 (Example: 1000 µS:5 nS)
Electronic Noise, Wet At 23 µS, noise <0.2 nS
At 1 µS, noise <0.1 nS
Filter Rise times from 0 to 10 s
Temperature Compensation Factory set at 1.7% per °C; programmable from 0.0 to 3.0% per °C
Cell Body PEEK
Cell Electrodes Passivated 316 stainless steel
Active Volume of Cell < 1.0 µL
Cell Operating Temperature 5 ºC above the DC detector compartment temperature; maximum of 60 ºC
Cell Maximum Operating Pressure 3 MPa (500 psi)
Signal Gain Ranges 0 to 180 µS, 0 to 1000 µS, and 0 to 15,000 µS
Optional Analog Output Full-Scale Ranges Three separate ranges from 0 to 15,000 µS

  

Electrochemical Detector  
Electronics Microprocessor-controlled digital signal processing
Detection Types Single- or dual-electrochemical detection. Dual-detection can be controlled either simultaneously or independently.
Noise < 1 pA (DC Amperometry)
10 pC (Integrated Amperometry)
Cell Drive Potential Settings -2.00 to 2.00 V in 0.001 V increments
Optional Analog Output Range 50 pC to 200 μC (Integrated Amperometry)
5 pA to 74 μA (DC Amperometry)
Cell Working Electrode Disposable gold, silver, or platinum
Non-disposable platinum, gold, silver, or glassy carbon
Cell Counter
Electrode
Titanium
Cell Reference Electrode pH-Ag/AgCl combination
Wetted Materials PEEK, titanium, Kel-F, polyetherimide, EPR, glass, high density
polyethylene (HDPE), ULTEM, Teflon working electrode
materials
Cell Volume at Working Electrode < 0.5 µL
Cell Maximum Operating Pressure 0.7 MPa (100 psi)

 

Thermal Compartment  
Temperature Control Range 5 to 85 °C in 0.1 °C increments (41 to 185 °F in 0.18 °F increments); thermo-electric control
Temperature Accuracy ±0.5 °C (0.9 °F)
Temperature Stability ±0.1 °C (0.18 °F)
Temperature Precision ±0.1 °C (0.18 °F)
Column Capacity Up to 3 columns; maximum length of 30 cm (11.8 in)
Heat-up Time < 20 min from 20 to 50 °C (68 to 122 °F)
Cooldown Time < 20 min from 50 to 20 °C (122 to 68 °F)
Control Provided by Chromeleon or Chromeleon Xpress software; the TC and the host computer are connected through USB (Universal Serial Bus)
I/O Interfaces 2 digital inputs, 2 programmable relay outputs
Injection Valve Electrically-activated Rheodyne TitanHP valve: 2-position, 6-port
or 2-position, 10-port (up to two valves can be installed)
Safety Features Humidity sensor and gas sensor
Temperature control and temperature sensors

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare