HP 5890 II GC with Wasson ECE special valve system

Item ID:

HP-G6-0390

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

Specification

 

Heated Devices 

 

-Five heated zonesstandard: Two detectors, Two inlets, one auxiliary 
– Methods stored:Two 
 


Split/Splitless Capillary 
 
-Range to 400°C in1°C increments 

-Back-pressuredesign permits independent adjustment of split flow rate without 
affecting columnflow 
-Septum purge builtin at 3 ml/min 
-Accepts columns upto 1.2-mm od 
-Multimode designincludes split and splitless injection 
-Splitless purgetime variable in 0.01-min elements 
 


Flame Ionization Detector 

 

-Range to 450°C 
-Grounded jet andcurrent limited design for operator safety 
-Push-button flameignition 
-Sensitive: 
-18 mCoul/gm carbon:nitrogen carrier, 0.018-in. id jet 
-15 mCoul/gm carbon:helium carrier, 0.018-in. id jet 
-22mCoul/gm carbon:nitrogen carrier, 0.018-in. id capillary jet 
-18 mCoul/gm carbon:helium carrier, 0.018-in. id capillary jet
-Minimum detectable:5 pg carbon/sec, nitrogen carrier at S/N=2 
-Linear dynamic range:+/- 10% over a 10 7 range with 0.018-in. id jet 
-Conditions: columnflow 50 ml/min, 45 ml/min H2, 650 ml/min air, propane 
sample 
 


Thermal Conductivity Detector 
 
-Range to 400 °C 

-Single-filament(single column) design has fluidic switching of reference and 
analytical carrierflows 
-Minimum detectable:400 pg/ml carrier — equivalent to 1 pmm neon in 1 ml air 
-Linear dynamicrange:+/- 5% over 105 range 
-Digital gainsetting time-programmable through the keyboard Conditions: 
detector 
-100 °C, 45 ml/minswitching and 30 ml/min analytical flow of helium, propane 
sample 
 


Flame Photometric Detector 
-Range to 300 °C 
– 100-530 u idcapillary columns fit through the transfer line to the base of the 
flame 
-Two combustionmodes: air/hydrogen or oxygen/hydrogen 
– Detector signaldisplay to view when flame is lit 
-Push-button flameignition 
– Sulfur mode:Sensitivity to 20 pg S/second, Range 103, Selectivity 105 g S/g C 
-o Phosphorus mode:Sensitivity to 0.9 pg P/second, Range 104, Selectivity 106 g 
P/g C 
 


Column Oven 
 
-Operating range: 4°C above ambient to 450 °C 

-Setpoint entry: 1°C for temperatures, 0.1 °C for program rates 
-Programming: Rates0.1 to 70 °C per min, 650 min maximum run time, Three 

ramps withinitial/final holds 

This refurbished HP 5890 II GC is in great condition.This GC has a Wasson-ECE Instrumentation designed special valve system for sample analysis. It has been tested at SpectraLab Scientific.
 
A 90 day warranty is included.
 

 

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare