O.I. Analytical 1020A Combustion TOC Analyzer

Item ID:

IOCO-TOC-1020A

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

The O.I. Analytical Model 1020A Total Organic Carbon Analyzer is an automated system for the selective analysis of total carbon (TC), total organic carbon (TOC), total inorganic carbon (TIC), and purgeable organic carbon (POC) in aqueous samples. The 1020A employs high temperature combustion oxidation, coupled with nondispersive infrared detection technology, for efficient, selective detection of carbon in a wide variety of matrices. This combustion instrument was designed specifically to comply with USEPA, Standard Methods, and ASTM methodologies for the analysis of water with higher levels of carbon as found in wastewater and marine waters.

Specifications

 

 

Type Specifications
Range* • 25 ppb–10,000 ppmC
Precision* • TC/TIC/TOC: 2% RSD, 100 ppb–5,000 ppm

• POC: 3% RSD

†Time of Analysis • TC/TIC/TOC: 5–7 min total

• POC: 5–7 min total

Particulates • <400 µm
Dimensions 17″ H x 13.5″ W x 22″ D
Analysis Modes • TC, TIC, TOC by difference, NPOC, and POC
Method • TC: 680°C with platinum catalyst

• TC: 900°C with zirconium packing

• TIC: acidification (H3PO4) and sparging

• Furnace temperature: adjustable, 200°–950°C in 1°C increments

Sample Introduction • Fixed volume sample loops: 25 µL, 50 µL, 100 µL, 200 µL, and 400 µL

• Sipper tube

• Autosampler (14- or 40-mL vials)

Oxygen Gas Requirements • <1 ppm CO2, CO, and THC at 50–60 psig (345–415 kPa)

• Recommended grade: UHP grade (99.998%) or better

• Consumption: approximately 550 mL/min

Nitrogen (for POC Option) Gas Requirements • <1 ppm CO2, CO, and THC at 50–60 psig (345–415 kPa)

• Recommended grade: UHP grade (99.998%) or better

• Consumption: approximately 70 mL/min

Reagent Requirements • Phosphoric acid (H3PO4), 5% v/v (uses 0.2 mL/sample under normal operating

conditions)

Environmental Requirements • Temperature: 10°–40°C

• Relative humidity: <90%, noncondensing

Detector • Nondispersive infrared cell

• Path length: 4.3″ (11 cm)

Output • Parallel and serial communications (RS-232-C)

• Auxiliary output for optional equipment

Options • WinTOC (Windows-based) software

• Solids TOC Analyzer

• POC Module

• Model 1051 Vial Autosampler with variable-speed stirring (53- or 88-position)

• Printer (dot matrix)

* The range and precision of analysis is affected by sample introduction, sample size, cleanliness of sample

containers, reagent purity, gas purity, and good laboratory practices.

† Time is dependent on sample properties and may vary with the matrix.

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare