info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688

PerkinElmer Clarus SQ 8T with Clarus 580 GC/MS System

Item ID:

PEGCMS-CLASQ8T

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

We can include compatible headspace autosampler upon request.

Description

With the Clarus SQ 8 GC/MS from PerkinElmer, laboratories of all types and sizes finally have a cutting-edge tool that offers both unsurpassed sensitivity and unparalleled stability. Why settle for compromised performance when there’s now a solution that gives you consistent ultra-trace detection limits time after time? Imagine the increased confidence in your results. Imagine the increased productivity in your lab.

Engineered around an advanced, fast quadrupole mass spectrometer, the Clarus SQ 8 GC/MS acquires a large number of spectra (12,500 amu/sec) across every GC peak. This enables the clear definition and quantification of extremely narrow chromatographic peaks to deliver exceptionally accurate and precise data. The instrument also gives you the widest mass range available in gas chromatography (1-1200 u), and detection limits never before seen with a single quadrupole GC/MS.

System Configurations Clarus SQ 8S Clarus SQ 8T Clarus SQ 8C
Ionization Type(s) EI EI EI/CI
Signal to Noise Specification 650:1 800:1 800:1
Turbomolecular Pump Capacity acity 75 L/sec 255 L/sec 255 L/sec
Pump-Down Time < 5 mins < 3 mins < 3 mins

The PerkinElmer Clarus SQ 8 Mass Spectrometer (MS) is a detector designed to be interfaced with the Clarus 580 and 680 Gas Chromatograph (GC). The Gas Chromatograph Mass Spectrometer (GC/MS) is controlled and data analyzed through the PerkinElmer TurboMassTM GC/MS software system.

Clarus SQ 8 T—Compatible with the Clarus 680 GC, with Electron Impact (EI) ionization and 255 L/sec turbomolecular pump.

Sensitivity

Test Amount Signal to Noise Performance
EI Full Scan 1 pg of octafluoronaphthalene 800:1

 

Hardware

Ion Source PerkinElmer SMARTsourceTM—Simplified Maintenance and Removal Technology (EI and CI compatible)
Filament MarathonTM—designed for long life
Mass Range 1.0 – 1,200 u (amu)
Detector Clarifi detector—long-life high sensitivity electron multiplier detector
Analyzer Quadrupole with pre-filter
Mass Stability + – 0.1 m/z over 48 hours
EI Voltage 10 – 100 eV
Vacuum Pumps 255 L/sec (nitrogen) air-cooled turbomolecular pump (230 L/sec helium pumping capacity)
Vacuum Gauge Single wide-range gauge (standard on all models)
Pump-down Time 255 L/sec turbomolecular pump: <3 minutes for air/water check, <90 minutes for quantitative stability
Temperature Settings SMARTsource: Settable 50 ˚C – 350 ˚C, GC transfer line: Settable 50 ˚C – 350 ˚C
Carrier Gas Flow Rate 255 L/sec turbomolecular pumping systems: 5 ml/min, 75 L/sec turbomolecular pumping systems: 1.5 ml/min
Mass Calibrant PFTBA (FC-43) gas, triazine (high mass applications), user selectable
MS Isolation Swafer Micro-Channel Flow Technology
Field Upgrades Positive/negative chemical ionization (255 L/sec), standard to large turbomolecular pump (75 L/sec to 255 L/sec), water cooling (all models)

 

Performance

MS Data Collection Full Scan, Selected Ion Monitoring (SIM), Simultaneous Full-Scan Selected Ion Monitoring (SIFI)
Scan Rate Fully variable up to 12,500 amu/sec
Acquisition Rate 100 points/sec (SIM)
Functions/Run 32 functions or 32 ions per function
Linear Dynamic Range 106 dependant on acquisition rate

 

Data system

Software TurboMassTM 6.0 designed for Windows 7 professional operating system
Methods Electronically transferable between all TurboMass and Clarus GC/MS systems
GC Acquisition Full control and data processing of a single GC/MS with up to 2 GC detectors
MS Tuning UltraTuneTM: Standard Tune environmental tuning optimized for EPA methods; Custom Tune user definable optimization
Reporting Included in all models with specialized reports for: Environmental and forensic applications.
Optional Software MS Libraries:      NIST Mass Spectral Library, including AMDIS Deconvolution, Wiley Mass Spectral Library Maurer/Pfleger/Weber Library of Drugs, Pollutants, Pesticides, and Metabolites

 

Advanced Processing: Ion Signature Deconvolution software

 

Physical

Power 120 VAC ± 10% @ 50/60 Hz ± 1% 1,000 VA, 230 VAC ± 10% @ 50/60 Hz ± 1% 1,000 VA
Temperature 10 ˚C – 30 ˚C (10 ˚C – 35 ˚C with water cooling option)
Relative Humidity 20 – 80 % non-condensing
Weight 49.9 kg (110 lbs)
Dimensions (HxWxD) Standalone MS: 50 x 32 x 77 cm (20 x 13 x 30 inches), Clarus SQ 8 T GC/MS (with Autosampler): 83 x 98 x 82 cm (33 x 39 x 32 inches)

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare