PerkinElmer Flexar FX UHPLC Autosampler

Item ID:

PE-ALSFX

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

The Flexar FX-UHPLC Autosampler is a powerful high-throughput UHPLC autosampler capable of operation at up to 18,000 psi. Comes standard with Peltier cooling, and a high-pressure injection valve for the most advanced UHPLC applications.

Hardware Specifications
Pressure limits 18,000 psi (1,240 bar)
Injection modes Fixed Loop: 5x sample overfill

Partial Fill: Variable injection volumes

µL Pickup: Injections without any excess sample waste

Injection volume Fixed Loop mode: 2 µL to 500 µL, depending on loop volume

Partial Fill mode: 0.1 µL to 2.45 mL (up to half loop volume)

µL Pickup mode (no sample waste): 1 µL to 977 µL, depending on loop volume

Injection cycle time As fast as 12 seconds in Partial Fill mode or 35 seconds in µL Pickup mode
Loop volumes 2 µL to 5 mL, 10 µL standard
Sample/flush syringes 100, 250, 500, 1000 and 2500 µL; 250 µL standard
Injection repeatability Fixed loop mode:

0.3% RSD

 

Partial loop mode:

0.5% RSD for ≥5 µL injections

1.0% RSD for 1-4 µL injections

 

µL Pickup mode:

0.5% RSD for ≥5 µL injections

1.5% RSD for 1 µL injection

Sample carryover <0.005% (caffeine), using programmable needle wash
Sample capacity 2 x 96-well high (deep) and low (shallow) microtiter plates; 100 2 mL vials; 200 0.2 mL vials; 25 6 mL vials
Tray types/ microtiter plates supported 100-vial tray: 2 mL vials (standard)

85-vial tray: 80 2 mL vials plus 5 6 mL vials

80-vial dilution tray: 80 2 mL vials plus 60 mL dilution tank

205-vial tray: 200 0.2 mL micro vials plus 5 2 mL vials

25-vial tray: 25 6 mL vials

2 x 96-well microtiter plate, high (deep)

2 x 96-well microtiter plate, low (shallow)

*All the above trays and plates are supported by Peltier Cooling and Heating options.

All trays and plates are supported by missing-vial detection.

Derivatization/serial dilution Both automated pre-column derivatization and serial dilution are supported using liquid mixing. No additional hardware is required other than an optional sample tray if desired. Tray used must provide large enough vials or a dilution tank for the diluent and/or derivatization reagent(s). Supported in Chromera® version 4.1 or higher, TotalChrom® and Agilent® EZChrom® 3.3.2
Needle height above vial well/plate 2-6 mm above vial well bottom or above bottom edge of microtiter plate
Injections per vial/plate Limited only by sample volume and injection mode
Wetted materials in contact w/sample Wetted materials in contact w/sample (Biocompatible flow path not available)
Needle washes/ flushes Programmable: up to 9 each of pre- and post-injection and between-method needle washes/flushes. All washes are followed by air drying of needle via built-in air compressor
Peltier options Cooling-only capability standard; Heating options available
Peltier temperature range Cooling-only: 4 °C to ambient -3 °C (will reach 4 °C ±2 °C with ambient temperature up to 25 °C at relative humidity of 80%).

Cooling/Heating: 4 °C to 40 °C (will reach 4 °C ±2 °C with Injection start synchronized to start pump program).

Pump piston injection synchronization Injection timing synchronized to pump piston position to optimize retention time reproducibility.*
Second solvent flush Supported in Chromera version 4.1 or higher

*Available only with Flexar FX-20 UHPLC Pump

Operating Specifications
Output Injection start, typically used to start pump program
Input Ready or Inject input, depending on how configured
Audible noise level LeAq <70 dB
Working temperature 10 °C to 40 °C (indoor use only)
Storage temperature -25 °C to 60 °C
Humidity 20% to 80% RH, non-condensing
Safety and EMC compatibility According to EC directives;

CSA (UL) approved

Power requirements 95-245 VAC, 50/60 Hz (±1%),

200 VA maximum power consumption

Viscosity range 0.1-5 cP
Dimensions (HxWxD) With Peltier cooling/heating option:

36 x 30 x 57.5 cm (14.2 x 11.8 x 22.6 in)

Without Peltier cooling/heating option:

36 x 30 x 51 cm (14.2 x 11.8 x 20.1 in)

Weight With Peltier cooling/heating option:

21.0 kg (46.2 lbs)

Without Peltier cooling/heating option:

19.0 kg (41.8 lbs)

Maximum weight which can be stacked on top of autosampler 65 kg (143 lbs)
Software, System Control and Communication Specifications
Service Manager software Autosampler setup and troubleshooting using dedicated user interface
CDS system environments supported TotalChrom and Chromera
Interface for TotalChrom environment RS232 via dotLINK
Interface for Chromera environment RS232

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare