Waters ACQUITY UPLC Photodiode Array (PDA) Detector

Item ID:

Waters-DT-0200

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

The Waters ACQUITY UPLC Photodiode Array (PDA) Detector is specifically designed for Waters ACQUITY UPLC System. With data rates up to 80 Hz and noise specifications as low as 10 μAU, the ACQUITY UPLC PDA Detector offers sensitivity that is unmatched by any other photodiode array detector on the market. Further, enhanced software control provides flexibility for simultaneous 2D and 3D operation in either Empower or MassLynx Software.

Item Specification
Wavelength range 190 to 500 nm
Optical resolution 1.2 nm
Digital resolution 1.2, 2.4, 3.6, 4.8, 6.0, 7.2, 8.4, 9.6, 10.8, 12.0
Wavelength accuracy ±1.0 nm
Wavelength Repeatability ±0.1 nm
Digital filter Variable with data rate
Order filter Fixed 340 nm to 500 nm
Noise (shunt in place of flow cell) 10 µAU, Peak to peak, 2 sec time constant, 30 sec
interval at 230 nm, 3.6 nm digital resolution, 2 Hz,
in a 240 micron medium shunt cell, 60 minute
warm-up time
Noise (10 mm
analytical flow cell)
14 µAU, Peak to peak, 2 sec time constant, 30 sec
interval at 230 nm, 3.6 nm digital resolution, 2 Hz,
0.5 mL/min, 10/90 Acetonitrile/water, 60 minute warm-up time
Drift (medium shunt cell and 10 mm analytical flow cell) 1000 µAU/hour, 2 sec time constant, 30 sec
interval at 230 nm, 3.6 nm digital resolution, 2 Hz,
60 minute warm-up time.
Environmental stability: ±2 °C/hour.
Analytical flow cell conditions 0.5 mL/min, 10/90
Acetonitrile/water.
Linearity < 5% at 2.0 AU, propylparaben series at 257 nm
Data rate 1, 2, 5, 10, 20, 40, and 80
Operating temperature 4 to 40 °C (39.2 to 104 °F)
Operating humidity <90%, noncondensing
Shipping and storage temperature −30 to 60 °C (−22 to 140 °F)
Shipping and storage humidity <90%, noncondensing
Acoustic noise (instrument generated) <65 dBA

This refurbished Waters ACQUITY UPLC Photodiode Array (PDA) Detector is in great condition. It has been tested at SpectraLab Scientific. A 90 day warranty is included.

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare