Introduced in 1995, Agilent’s 1100 series HPLC system is an extremely popular HPLC. They are robust, durable, and versatile. The 1100 HPLC series supports efficient mixing and pulse-free pump action as well as advanced diagnostics and data analysis software. Many additional features include modular binary and quadrary pump configurations, a high speed proportioning valve, and pre-configured vacuum degasser, making the 1100 a high functioning reliable assett in the laboratory. The system is easy to use at a low cost.

This system includes:

This Agilent 1100 HPLC System is in great condition. It has been tested at SpectraLab Scientific.
A 90 day warranty is included.

Agilent 1100 Series HPLC System Manual PDFs


Performance Specifications

 

 

G1315 Diode Array Detector
Type Specification
Detection type 1024-element photodiode array
Light source Deuterium and tungsten lamps
Wavelength range 190 – 950 nm
Short term noise (ASTM) Single and Multi-Wavelength ± 1 × 10-5 AU at 254 and 750 nm
Drift 2 × 10-3 AU/hr at 254 nm
Linear absorbance range > 2 AU (upper limit)
Wavelength accuracy ± 1 nm
Wavelength bunching 1 – 400 nm
Slit width 1, 2, 4 , 8, 16 nm
Diode width < 1 nm
Flow cells Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum
500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
Control and data evaluation Agilent ChemStation for LC
Analog outputs Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintenance Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages.
Electronic records of maintenance and errors.
Verification of wavelength accuracy with built-in holmium oxide filter.
Housing All materials recyclable.
G1312A Binary Pump
Type Specification
Hydraulic system Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
Setable flow range Setpoints 0.001 – 5 ml/min, in 0.001 ml/min increments
Flow range 0.1 – 5.0 ml/min
Flow precision < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
Pressure Operating range 0 400 bar (0 – 5880 psi) up to 5 ml/min
Pressure pulsation < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
Compressibility compensation User-selectable, based on mobile phase compressibility
Recommended pH range 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient formation High-pressure binary mixing, delay volume 180 – 480 µl without mixer, 600 – 900 µl with mixer, dependent on back pressure
Composition range 1 – 99 % or 5 µl/min per channel, whatever is greater
Composition precision < 0.2 % RSD, at 0.1 and 1 ml/min
Control and data evaluation Agilent ChemStation for LC
Analog output For pressure monitoring, 2 mV/bar, one output
Communications Controller-area network (CAN), GPIB, RS-232C, AP
Safety and maintenance Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system.
Low voltages in major maintenance areas.
GLP features Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages.
Electronic records of maintenance and errors.
Housing All materials recyclable.

 

G1329A Thermostated Autosampler (100 µl metering head)
Type Specification
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range 0.1 – 100 µl in 0.1 µl increments
Up to 1500 µl with multiple draw (hardware modification required)
Replicate injections 1 – 99 from one vial
Precision Typically < 0.5 % RSD of peak areas from 5 – 100 µl,
typically < 1 % RSD of peak areas from 1 – 5 µl
Minimum sample volume 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover Typically < 0.1 %, < 0.05 % with external needle cleaning
Sample viscosity range 0.2 – 50 cp
Replicate injections per vial 1 – 99
Sample capacity 100 × 2-ml vials in 1 tray
40 × 2-ml vials in ½ tray
15 × 6-ml vials in ½ tray (Agilent vials only)
Injection cycle time Typically 50 s depending on draw speed and injection volume

 

G1329A Thermostated Autosampler (900 µl metering head)
Type Specification
Pressure Operating range 0-20 MPa (0-200 bar, 0-2950 psi)
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range 0.1 – 900 µl in 0.1 µl increments (recommended 1 µl increments)
Up to 1800 µl with multiple draw (hardware modification required)
Replicate injections 1 – 99 from one vial
Precision Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
typically < 1% RSD of peak areas from 2000 – 5000 µl,
Typically < 3% RSD of peak areas from 1 – 5 µl
Minimum sample volume 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover Typically < 0.1%, < 0.05% with external needle cleaning
Sample viscosity range 0.2 – 50 cp
Sample capacity 100 × 2-ml vials in 1 tray
40 × 2-ml vials in ½ tray
15 × 6-ml vials in ½ tray (Agilent vials only)
Injection cycle time Typically 50s depending on draw speed and injection volume

 

G1316A Thermostated Column Compartment
Type Specification
Temperature range 10 degrees below ambient to 80 °C
Temperature stability ± 0.15 °C
Temperature accuracy ± 0.8 °C
± 0.5 °C
Column capacity Three 30 cm
Warm-up/cool-down time 5 minutes from ambient to 40 °C
10 minutes from 40 – 20 °C
Dead volume 3 µl left heat exchanger
6 µl right heat exchanger
Dimensions (h × w × d) 140 × 410 × 435 mm
Weight 10.2 kg
Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote:
ready, start, stop and shut-down signals, LAN optional
Safety and maintenance Extensive diagnostics, error detection and display (through
control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of
pumping system. Low voltages in major maintenance areas.
GLP features Column-identification module for GLP documentation of column type
Housing All materials recyclable

 

G1322A Degasser
Type Specification
Maximum flow rate 10 ml/min per channel
Number of channels 4
Internal volume per channel Typically 12 ml per channel
Materials in contact with solvent PTFE, PEEK
pH range 1 – 14
Analog output (AUX) For pressure monitoring, range 0 – 3V

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare