Agilent 1200 Series Nano HPLC System with G1315B DAD

Item ID:

1200-Nano-G1315B

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

This HP/ Agilent 1200 Series Nano HPLC System comes with the followings:

 

This system is in great condition. It has been tested at SpectraLab Scientific. A 90 day warranty is included.

 

 

Performance Specifications:

G2226A Nano Pump
Type Specification
Hydraulic system Two dual piston in series, with proprietary servo-controlled variable

stroke drive, floating piston, active inlet valve, solvent selection valve

and electronic flow control for flow rates from 0.1 to 1 µl/min

Settable column flow range 0.01 – 4 µl/min

1 – 2500 µl/min (with the electronic flow control bypassed)

Recommended column flow range 0.1 – 1 µl/min

200 – 2500 µl/min (with the electronic flow sensor bypassed)

Optimum composition range 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
Composition precision < 0.2 % SD, at 500 nl/min (default settings),

Minimum primary flow/pump channel is 5 µl/min

Delay volume Typically 300 nl from the electronic flow control to the pump outlet for flow rates up to 4 µl/min. For flow rates up to 4 µl/min and electronic flow control active: primary flow path 180 – 480 µl; system pressure dependent (default settings; calculated volume)Typically 180 to 480 µl (system pressure dependent) for flow rates up to 2.5 ml/min. (default settings; calculated volume)
Pressure range 20 to 400 bar (5880 psi) system pressure
Compressibility compensation User-selectable, based on mobile phase compressibility
Recommended pH range 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
Control and data evaluation Agilent ChemStation for LC
Analog output Communications For pressure monitoring, 2 mV/bar, one output

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready,

start, stop and shut-down signals, LAN optional

Safety and maintenance Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP features Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
Housing All materials recyclable.
G1379B Degasser
Type Specification
Maximum flow 5 ml/min per channel
Number of channels 4
Internal volume Typically 1 ml per channel
pH range 1-14
RS232 output For diagnosis purpose
Material in contact with Solvents PTFE, FEP, PEEK
G1377A Micro WPS
Type Specification
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range 0.01– 8 µl in 0.01 µl increments with the small loop capillary 0.01–40 µl in 0.01 µl increments with the extended loop capillary
Precision Typically < 0.5% RSD of peak areas from 5 – 40 µl, Typically < 1% RSD from 1 – 5 µl Typically < 3% RSD from 0.2 – 1 µl
Pressure range 400 bar (5880 psi)
Sample viscosity range 0.2 – 5 cp
Sample capacity 2 × well-plates (MTP) + 10 × 2 ml vials

108 x 2-mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials

30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials

54 Eppendorf tubes (0.5/1.5/2.0 mL) in 2 x 27 Eppendorf tube plate

Injection cycle time Typically < 30 s using following standard conditions: Default draw

speed: 4 µl/min Default eject speed: 10 µl/min Injection volume:

0.1 µl

Carry-over Typically < 0.05% using the following conditions: Column:

150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase:

Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection

volume: 1 µl caffeine (=25 ng caffeine), 1 µl water to test carry over

Outside wash of needle before injection: 20 sec with water using flush port

G1316A TCC
Type Specification
Temperature range 10 degrees below ambient to 80 °C

up to 80 °C: flow rates up to 5 ml/min

Temperature stability ± 0.15 °C
Temperature accuracy ± 0.8 °C

± 0.5 °C (with calibration)

Column capacity Three 30 cm
Warm-up/cool-down time 5 minutes from ambient to 40 °C

10 minutes from 40 – 20 °C

Dead volume 3 µl left heat exchanger

6 µl right heat exchanger

Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module
Safety and maintenance Extensive diagnostics, error detection and display (through control module and Agilent Chem Station), leak detection, safe leak handling, leak output signal for shut down of pumping system. Low voltages in major maintenance areas.
GLP features Column-identification module for GLP

documentation of column type

Housing All materials recyclable
G1315B Diode Array Detector
Wavelength range 190-950 nm
Light source Deuterium and tungsten lamps
Detection type 1024 – element photo diode array
Short term noise (ASTM) single & mult-wavelength ± 1° x 10-5 AU at 254 and 750 nm
Drift 2° x 10-3 AU / hr at 254 nm
Linear absorbance range > 2 AU (upper limit)
Wavelength accuracy ± 1 nm
Wavelength bunching 1 – 400 nm
Diode width < 1 nm
Flow cells Standard: 13µl volume 10 mm cell path length and 120 bar (1760 psi) pressure maximum

Semi-Micro: 5µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum

Micro: 2µl volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum

High Pressure: 1.7µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure max.

80 nano: 0.08µl volume, 100 mm cell path length and 50 bar (725 psi) pressure max.

500 nano: 0.5µl volume, 10 mm cell path length and 50 bar (725 psi) pressure max.

Analog outputs Recorder / integrator: 10 mV or 1 V, output range

0.001 – 2 AU, two outputs

Control and data evaluation Agilent Chem station for LC
Slit width 1, 2, 4, 8, 16 nm
Communication types CAN, GBIP, RS-232C, APG, Remote: ready, start, stop and shut down
Wavelength range 190-950 nm
Light source Deuterium and tungsten lamps
Detection type 1024 – element photo diode array
Short term noise (ASTM) single & mult-wavelength ± 1° x 10-5 AU at 254 and 750 nm
Drift 2° x 10-3 AU / hr at 254 nm
Linear absorbance range > 2 AU (upper limit)

 

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare