This HP / Agilent 1200 Series HPLC system comes with the following:

  • Solvent Tray
  • Agilent 1200 Series G1379B Degasser
  • Agilent 1200 Series G1312A Bin Pump
  • Agilent 1200 G1367B HiP ALS Autosampler
  • Agilent 1200 G1330B FC/ALSTherm
  • Agilent 1200 Series G1316A TCC
  • Agilent 1200 Series G1315B DAD
  • PC with Suitable software and all essential cables required for full operation

Agilent 1200 series G1379B Degasser

Type Specification
Maximum flow rate 0 – 5 ml/min per channel
Number of channels 4
Internal volume per channel Typically 1 ml per channel
Materials in contact with solvent PTFE, FEP,PEEK
pH range 1 – 14
RS-232 output For diagnostic purposes

Agilent 1200 Series G1312A Bin pump

Type Specification
Hydraulic system Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
Setable flow range Setpoints 0.001 – 5 ml/min, in 0.001 ml/min increments
Flow range 0.1 – 5.0 ml/min
Flow precision <0.07% RSD, or <0.02 min SD whatever is greater, based on retention time at constant room temperature
Flow accuracy +1% of 10µl/min whatever is greater
Pressure Operating range 0 400 bar (0-5880 psi) up to 5 ml/min
Pressure pulsation < 2% amplitude (typically < 1%), at 1 ml/min isopropanol, at all pressures > 1 MPa
Compressibility compensation User-selectable, based on mobile phase compressibility
Recommended pH range 1.0 – 12.5, solvents with pH <2.3 should not contain acids which attack stainless steel
Gradient formation High-pressure binary mixing, delay volume 180-480 µl without mixer, 600 – 900 µl with mixer, dependent on back pressure
Composition range 1 – 99 % or 5 µl/min per channel, whatever is greater
Composition precision <0.5% absolute
Composition accuracy 0.15% RSD, at 1 ml/min
Control and data evaluation Agilent ChemStation for LC
Analog output For pressure monitoring, 2mV/bar, one output
Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintenance Extensive diagnostics, error detection and display (through handheld controllers G4208A, G1323B and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltage in major maintenance areas
GLP features Early maintenance feedback (EMF) for continuous tracking of instruments usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
Housing All materials recyclable

Agilent 1200 G1367B HiP ALS Autosampler

Type Specification
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range 0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
Precision Typically < 0.25% RSD from 5 – 100 µl, Typically < 1% RSD from 1 – 5 µl variable volume
Pressure range 400 bar (5880 psi)
Sample viscosity range 0.2 – 5 cp
Sample capacity 2 × well plates (MTP) + 10 × 2 ml vials 108 x 2-mL vials in2 x 54 vial plate plus 10 additional 2 mL vials 30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 x 27 Eppendorf tube plate

Also compatible with the Agilent 1200 Series sample capacity extension for further expansion of the sample capacity

Injection cycle time Typically < 30 s using following standard conditions: Default draw speed: 200 µl/min Default eject speed: 200 µl/min Injection volume: 5 µl
Carry-over Typically < 0.01% using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm Mobile phase: Water/Acetonitrile = 80/20 Flow rate: 1 ml/min Injection volume: 1 µl caffeine (1 mg/ml), 5 µl water to test carryover Outside wash of needle before injection: 20 sec with water using flush port

Agilent 1200 series G1316A TCC

Type Specification
Temperature range 10 degrees below ambient to 80 °C

up to 80 °C: flow rates up to 5 ml/min

Temperature stability ± 0.15 °C
Temperature accuracy ± 0.8 °C

± 0.5 °C (with calibration)

Column capacity Three 30 cm
Warm-up/cool-down time 5 minutes from ambient to 40 °C

10 minutes from 40 – 20 °C

Dead volume 3 µl left heat exchanger

6 µl right heat exchanger

Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module
Safety and maintenance Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP features Column-identification module for GLP

documentation of column type

Housing All materials recyclable

Aglient 1200 series G1315B DAD

Wavelength range 190-950 nm
Light source Deuterium and tungsten lamps
Detection type 1024 – element photodiode array
Short term noise (ASTM) single & mult-wavelength ± 1° x 10-5 AU at 254 and 750 nm
Drift 2° x 10-3 AU / hr at 254 nm
Linear absorbance range > 2 AU (upper limit)
Wavelength accuracy ± 1 nm
Wavelength bunching 1 – 400 nm
Diode width < 1 nm
Flow cells Standard: 13µl volume 10 mm cell path length and 120 bar (1760 psi) pressure maximum

Semi-Micro: 5µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum

Micro: 2µl volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum

High Pressure: 1.7µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure max.

80 nano: 0.08µl volume, 100 mm cell path length and 50 bar (725 psi) pressure max.

500 nano: 0.5µl volume, 10 mm cell path length and 50 bar (725 psi) pressure max.

Analog outputs Recorder / integrator: 10 mV or 1 V, output range

0.001 – 2 AU, two outputs

Control and data evaluation Agilent Chemstation for LC
Slit width 1, 2, 4, 8, 16 nm
Communication types CAN, GBIP, RS-232C, APG, Remote: ready, start, stop and shut down
Wavelength range 190-950 nm
Light source Deuterium and tungsten lamps
Detection type 1024 – element photodiode array
Short term noise (ASTM) single & mult-wavelength ± 1° x 10-5 AU at 254 and 750 nm
Drift 2° x 10-3 AU / hr at 254 nm
Linear absorbance range > 2 AU (upper limit)

Please feel free to contact our professional team members if you have any concern.

Your satisfaction is our first priority and we do appreciate your preference and look forward to serving you in the near future.

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare