info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688

HP Agilent 1100, G2226A Nano HPLC System

Item ID:

HP-1SY-0930

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

This Agilent 1100 System is equipped with the following:

  • G1322A Degasser and Solvent  Tray
  • G2226A NanoBin Pump
  • G1389 Well Place Autosampler
  • G1316A Column compartment
  • G1315B DAD with nano flow cell
  • Suitable software, PC, LAN Connection
  • all necessary cables required for full operation

Agilent 1100 NanoBin Pump

Type Specification
Hydraulic system Two dual piston in series, with proprietary servo-controlled variable
stroke drive, floating piston, active inlet valve, solvent selection valve
and electronic flow control for flow rates from 0.1 to 1 µl/min
Settable column flow Range 0.01 – 4 µl/min
1 – 2500 µl/min (with the electronic flow control bypassed)
Recommended column flow range 0.1 – 1 µl/min
200 – 2500 µl/min (with the electronic flow sensor bypassed)
Optimum composition Range 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
Composition precision < 0.2 % SD, at 500 nl/min (default settings),
Minimum primary flow/pump channel is 5 µl/min
Delay volume Typically 300 nl from the electronic flow control to the pump outlet for flow rates up to 4 µl/min. For flow rates up to 4 µl/min and electronic flow control active: primary flow path 180 – 480 µl; system pressure dependent (default settings; calculated volume)Typically 180 to 480 µl (system pressure dependent) for flow rates up to 2.5 ml/min. (default settings; calculated volume)
Pressure range 20 to 400 bar (5880 psi) system pressure
Compressibility compensation User-selectable, based on mobile phase compressibility
Recommended pH Range 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries
Control and data Evaluation Agilent ChemStation for LC
Analog output For pressure monitoring, 2 mV/bar, one output
Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready,
start, stop and shut-down signals, LAN optional
Safety and maintenance Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP features Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
Housing All materials recyclable

Agilent 1100 Series G1389 U Well PlaceAutosampler

Type Specification
Sample capacity 100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)
Settable injection volume 0.01 to 8 µl with small loop capillary
0.01 to 40 µl with extended loop capillary
Precision Typically < 0.5 % RSD from 5 to 40 µl
Typically < 1 % RSD from 1 to 5 µl
Typically < 3 % RSD from 0.2 to 1 µl
Minimum sample volume 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in
300 µl microvials
Carryover Typically < 0.1 % without automated needle wash
Typically < 0.05 % with external needle cleaning and 1 µl injection Volume
Sample viscosity range 0.2 – 5 cp
Recommended pH-range 1.0 – 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries
Material in contact with
Solvent
Stainless steel, sapphire, PTFE, PEEK, fused silica, Vespel
GLP features Early maintenance feedback (EMF),electronic records of maintenance and errors
Communications Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Housing All material recyclable

Agilent 1100 Series G1315B DAD with nano flow cell

Type Specification
Detection type 1024-element photodiode array
Light source Deuterium and tungsten lamps
Wavelength range 190 – 950 nm
Short term noise (ASTM)
Single and Multi-Wavelength
± 1 × 10-5AU at 254 and 750 nm
Drift 2 × 10-3AU/hr at 254 nm
Linear absorbance range > 2 AU (upper limit)
Wavelength accuracy ± 1 nm
Wavelength bunching 1 – 400 nm
Slit width 1, 2, 4 , 8, 16 nm
Diode width < 1 nm
Flow cells Standard: 13 µl volume, 10 mm cell path length
and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5 µl volume, 6 mm cell path length
and 120 bar (1760 psi) pressure maximum
Micro: 2 µl volume, 3 mm cell path length and
120 bar (1760 psi) pressure maximum
High pressure: 1.7 µl volume, 6 mm cell path
length and 400 bar (5880 psi) pressure maximum
80 nano: 0.08 µl volume, 10 mm cell path length
and 50 bar (725 psi) pressure maximum
500 nano: 0.5 µl volume, 10 mm cell path length
and 50 bar (725 psi) pressure maximum
Control and data evaluation Agilent ChemStation for LC
Analog outputs Recorder/integrator: 100 mV or 1 V, output range
0.001 – 2 AU, two outputs
Communications Controller-area network (CAN), GPIB, RS-232C,
APG Remote: ready, start, stop and shut-down
signals, LAN optional
Safety and maintenance Extensive diagnostics, error detection and display
(through control module and ChemStation), leak
detection, safe leak handling, leak output signal
for shutdown of pumping system. Low voltages in
major maintenance areas.
GLP features Early maintenance feedback (EMF) for continuous
tracking of instrument usage in terms of lamp burn
time with user-settable limits and feedback
messages. Electronic records of maintenance and
errors. Verification of wavelength accuracy with
built-in holmium oxide filter.
Housing All materials recyclable

Agilent 1100 Series Column compartment G2226A

>Type >Specification
Temperature range 10 degrees below ambient to 80 °C
up to 80 °C: flow rates up to 5 ml/min
Temperature stability ± 0.15 °C
Temperature accuracy ± 0.8 °C
± 0.5 °C (with calibration)
Column capacity Three 30 cm
Warm-up/cool-down time 5 minutes from ambient to 40 °C
10 minutes from 40 – 20 °C
Dead volume
3 µl left heat exchanger
6 µl right heat exchanger
Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module
Safety and maintenance Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP features Column-identification module for GLP
documentation of column type
Housing All materials recyclable

The equipment has been tested and refurbished.

Please ask us about different warranty options for this system.

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare