Thermo TSQ Quantiva Triple Quadrupole Mass Spectrometer with Vanquish MD UHPLC
3-12 month warranty
Service options & contracts available
To sell, trade-in, or service your equipment
How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us
Request Quote/ Offer
Estimate Shipping Time
Canada & U.S.: 3-5 business days
International: 5-10 business days
Tariff-Free Shipping to the U.S.!
Uncompromised sensitivity—Enhanced sensitivity, wide dynamic range, faster scan speeds, and advances in tool-free maintenance and robustness deliver the highest performance and productivity for trace analysis. This Thermo Scientific TSQ Quantiva Triple Quadrupole Mass Spectrometer is in good condition. Two systems are available in stock.
System Includes:
- Thermo TSQ Quantiva Triple Quadrupole Mass Spectrometer
- Thermo Vanquish MD UHPLC including autosampler, binary pump and column compartment.
- PC with DATA
- 2 Sogevac SV65 BI FC Rough Pumps
Sensitivity
Positive Electrospray (HESI): A 2 μL injection of a 500 fg/μL reserpine solution on a Thermo Scientific™ Hypersil GOLD™ aQ 20 x 2.1 mm 1.9 μm particle packed column at a flow rate of 300 μL/min 70/30 methanol/water with 0.05% formic acid will produce a minimum signal-to-noise ratio of 200,000:1 for the transition of the protonated molecule at m/z 609.3 to the fragment ion at m/z 195.1 when operated in selected-reaction monitoring (SRM) mode with Q1 and Q3 resolution set to 0.2 and 0.7 Da FWHM respectively.
Atmospheric Pressure Chemical Ionization (APCI): A 2 μL loop injection of a 500 fg/μL reserpine solution on a Thermo Scientific Hypersil GOLD aQ 20 x 2.1 mm 1.9 μM particle packed column at a flow rate of 300 μL/min 70:30 methanol/water with 0.05% formic acid will produce a minimum signal-to-noise ratio of 50,000:1 for the transition of the protonated molecular ion at m/z 609.3 to the fragment ion at m/z 19 5 .1 when operated in selected reaction monitoring (SRM) mode with Q1 and Q3 resolution both set to 0.7 Da FWHM.
Negative Electrospray (nESI): A 2 μL loop injection of a 500 fg/uL chloramphenicol solution will produce a minimum signal-to-noise ratio of 200,000:1 for the transition of the deprotonated molecular ion at m/z 321.0 to the fragment ion at m/z 152.0 when operated in selected reaction monitoring mode (SRM) with Q1 and Q3 resolution set to 0.7 Da FWHM.
Mass Range: m/z 10 –1800
Resolution: Q1 and Q3 adjustable to 0.2 Da peak width (FWHM) across the entire mass range
Scan Rate: 15,000 amu/second at a resolution of 2 FWHM500 SRM/second (for any resolution from 0.2 through 2.0 FWHM)25msec polarity switching
Mass Stability: Mass assignment will be within ±0.05 Da over a 24 hour period. The laboratory room temperature must be maintained between 18–27 °C (65–81 °F). The room temperature may not change by more than 5 °C (9 °F) during this period.
People Also View
Related products
-
Thermo Finnigan Quest GCQ Plus Series EI/CI MS with Trace 2000 GC with ECD and AS 2000 Autosampler
Item ID: Pre-ownedSold Out
SpectraLab Scientific Inc
Established in 2003,
SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.
Our Services
Spectralab Scientific Inc. offers a variety of laboratory services to help you get started. Whether you’re setting up a new labs or developing your start up, we can help you overcome obstacles and provide turn-key solutions.
Repair Service
Parts and repairs for analytical equipment
Qualifications
IQ/OQ/PQ centered on compliance and data integrity
Service Contracts
Protect your lab and minimize downtime
Warranty
Up to 5 years warranty on most of the equipment
Installation & Training
Hassle-free setup & training from our professionals
Maintenance
Yearly PM to ensure peak performance

















