Thermo TSQ Quantiva Triple Quadrupole Mass Spectrometer with Vanquish MD UHPLC

Item ID:

THERMO-TSQ-QTV

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

Request Quote/ Offer

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

Uncompromised sensitivity—Enhanced sensitivity, wide dynamic range, faster scan speeds, and advances in tool-free maintenance and robustness deliver the highest performance and productivity for trace analysis. This Thermo Scientific TSQ Quantiva Triple Quadrupole Mass Spectrometer is in good condition. Two systems are available in stock.

System Includes:

  • Thermo TSQ Quantiva Triple Quadrupole Mass Spectrometer
  • Thermo Vanquish MD UHPLC including autosampler, binary pump and column compartment.
  • PC with DATA
  • 2 Sogevac SV65 BI FC Rough Pumps

Sensitivity

Positive Electrospray (HESI): A 2 μL injection of a 500 fg/μL reserpine solution on a Thermo Scientific™ Hypersil GOLD™ aQ 20 x 2.1 mm 1.9 μm particle packed column at a flow rate of 300 μL/min 70/30 methanol/water with 0.05% formic acid will produce a minimum signal-to-noise ratio of 200,000:1 for the transition of the protonated molecule at m/z 609.3 to the fragment ion at m/z 195.1 when operated in selected-reaction monitoring (SRM) mode with Q1 and Q3 resolution set to 0.2 and 0.7 Da FWHM respectively.

Atmospheric Pressure Chemical Ionization (APCI): A 2 μL loop injection of a 500 fg/μL reserpine solution on a Thermo Scientific Hypersil GOLD aQ 20 x 2.1 mm 1.9 μM particle packed column at a flow rate of 300 μL/min 70:30 methanol/water with 0.05% formic acid will produce a minimum signal-to-noise ratio of 50,000:1 for the transition of the protonated molecular ion at m/z 609.3 to the fragment ion at m/z 19 5 .1 when operated in selected reaction monitoring (SRM) mode with Q1 and Q3 resolution both set to 0.7 Da FWHM.

Negative Electrospray (nESI): A 2 μL loop injection of a 500 fg/uL chloramphenicol solution will produce a minimum signal-to-noise ratio of 200,000:1 for the transition of the deprotonated molecular ion at m/z 321.0 to the fragment ion at m/z 152.0 when operated in selected reaction monitoring mode (SRM) with Q1 and Q3 resolution set to 0.7 Da FWHM.

Mass Range: m/z 10 –1800

Resolution: Q1 and Q3 adjustable to 0.2 Da peak width (FWHM) across the entire mass range

Scan Rate: 15,000 amu/second at a resolution of 2 FWHM500 SRM/second (for any resolution from 0.2 through 2.0 FWHM)25msec polarity switching

Mass Stability: Mass assignment will be within ±0.05 Da over a 24 hour period. The laboratory room temperature must be maintained between 18–27 °C (65–81 °F). The room temperature may not change by more than 5 °C (9 °F) during this period.

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare