info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688

Waters Alliance e2695 HPLC system with Waters 2489 UV/Vis Detector

Item ID:

Waters-SY-0435

Manufacturer

Condition

Refurbished

How do we Refurbish Lab Equipment?
Looking for further assistance? Contact Us

Price:

$18000 USD

Estimate Shipping Time

Canada & U.S.: 3-5 business days
International: 5-10 business days

Tariff-Free Shipping to the U.S.!

This Waters Alliance e2695 HPLC system comes with Waters 2489 UV/Vis Detector. They are in great condition and have been tested at SpectraLab Scientific.

Specifications:

Solvent Management
Number of solvents One to four
Solvent conditioning Vacuum degas, two operating modes, four chambers, 500 µL internal volume per chamber
Flow rate range 0.000 to 10.000 mL/min (0.050 to 5.000 mL/min typical) in 0.001 mL/min increments
Compressibility compensation Automatic continuous
System delay volume < 650 µL, independent of backpressure at 1 mL/min
Plunger seal wash Integral, active, programmable
Gradient profiles 11 gradient curves (including linear, step [2], concave [4], and convex [4])
Dry prime/ wet prime Automatic front panel control, SystemPREP function for automatic solvent(s) purge
Flow ramping Time (0.01 to 30.00 min in 0.01 min increments) to reach maximum flow rate
Maximum operating pressure 5000 psi (345 bar) (0.010 to 3.000 mL/min) programmable upper and lower limits
Composition range 0.0% to 100.0%, in 0.1% increments
Composition accuracy +0.5% absolute, independent of backpressure (proportioning valve pair test,[degassed methanol: methanol/proplyparaben, 2.0 mL/min, 254nm])
Composition precision <0.15% RSD or <0.02 min SD, six replicates, based on retention time or volumetric measures (0.200 to 5.000 mL/min),isocratic premix
Flow accuracy +1% or 10 µL/min, which is greater, 0.200 to 5.000 mL/min,

 

Sample management
Number of samples vials 120 vials, configured in five carousels of 24 vials each
Number of sample injections 1 to 99 injections per sample vial
Sample delivery precision Typically <0.5% RSD, 5 to 80 µL (degassed methanol: water 60:40 dial-a-mix, 1 mL/min, six replicates, phenone mix, 254 nm)
Sample carryover <0.01% for caffeine, under specified conditions
Injection needle wash Integral, active, programmable
Injection accuracy +1µL (+2%)(50µL, N-6), sample: 100% degassed water, analytical solvent: 100% degassed methanol
Standard sample vial 2 mL
Advanced operations Priority samples, auto additions, auto standards
Injection volume range 0.1 to 100 µL, standard; 0.1 to 2000 µL, with optional sample loop
Injector linearity >0.999 coefficient of deviation (1.000 to 100.000 µL)
Minimum sample required 10 µL, using low volume inserts
Sample temperature control (optional) 4 to 40°C, programmable in 1°C increments
Column heater (optional) 20 to 65 °C, in 1 °C increments (5°C above ambient)
Column heater/cooler(optional) Ambient minus 15°C to 4°C (whichever is greatest) up to 65°C, in 1°C increments

Waters 2489 UV/Vis detector

Condition Specification
Wavelength range 190 to 700 nm
Bandwidth <5 nm
Wavelength accuracy +1.0 nm
Wavelength repeatability +0.1 nm
Single λ dry noise <5 µAU

(at 230 nm, 1 –second digital filter, 30-second segments, 10-Hz data rate, analytical cell)

Wet noise <8 µAU

(at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)

Dual channel noise (dry) <35 µAU

(measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; dry, analytical cell)

Dual channel noise (wet) <45 µAU

(measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; 1 ml/min, flow of acetonitrile, analytical cell)

Linearity <5% at 2.5 AU, propylparaben at 257 nm
Drift 1.0 x 10-4 AU/hr. max (∆T = +2°C/hr.)
Thermal drift 1.0 x 10-4 AU/°C max (∆T = +2°C/hr.)
Sensitivity setting range 0.0001 to 4.0000 AUFS
Filter setting range Single-wavelength: 0.1 to 5.0 seconds

Dual-wavelength: 1 to 50 seconds

Time-constant To 5.0-second Hamming filter
Digital data rates 1,2,5,10,20,40,80 Hz (single channel)

1,2 Hz (dual channel)

Analog output data rates (single λ mode) 10,20,40,80 Hz (channel A)

10 Hz only (channel B)

Lamp source 30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)
Second-order filter Automatic for wavelengths > 370 nm
Wavelength calibration filter Erbium filter, used at startup or on demand
Flow cell TaperSlit flow cell design
Nitrogen purge Purge fitting present on optics bench
Path length 10 mm (standard analytical)
Cell volume 10 µL (standard analytical)
Pressure limit 6895 kPa (69 bar,1000 psi)
Materials 316 stainless steel, fused silica, Tygon
Operating temperature 4 to 40 °C (39 to 104 °F)
Operating humidity 20% to <95%, noncondensing
Shipping and storage -30 to +60 °C
Shipping and storage humidity 0% to <95% noncondensing

SpectraLab Scientific Inc
Established in 2003,

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare