Skip to content

🇺🇸 Spectralab Scientific Expands to the U.S.! 🇺🇸 Dismiss

info@spectralabsci.com
+1 905-946-8066 | N/A Toll Free: +1 886-777-3688
My Account
SpectraLab Scientific Inc.
  • Product
    All LC System & Parts
    LC Systems

    High-Performance Liquid Chromatography

    IC Systems

    Ion Chromatography

    LC Components
    • Detectors
    • Autosamplers
    • Pumps
    • Degassers
    • Column Compartments
    • Fraction Collectors
    • Others

    LC-MS

    Liquid Chromatography-Mass Spectrometry

    FPLC

    Fast Protein Liquid Chromatography

    LC Parts

    • LC Columns
    • Agilent parts
    • Thermo parts
    • Waters parts
    • Shimadzu parts
    • Other
    All GC System & Parts

    GC systems

    Gas Chromatography

    microGCs​ (/ μGC)

    Micro Gas Chromatography

    Autosamplers

    HPLC, GC, MS, ICP, TOC and more

    GC-MS

    Gas Chromatography-Mass Spectrometry

    Purge and Trap

    GC Parts

    GC columns and parts

    All Spectroscopy System & Parts

    FTIR

    Fourier Transform Infrared Spectroscopy

    UV-Vis

    Ultraviolet–Visible spectrophotometry

    ICP-MS

    Inductively Coupled Plasma-Mass Spectrometry

    AAS

    Atomic Absorption Spectroscopy

    ICP

    Inductively Coupled Plasma

    Spectroscopy Accessories

    Other Spectrometer

    All MS Systems & Parts

    LC-MS or LC-MS/MS

    Liquid Chromatography-Mass Spectrometer/MS

    GC-MS or GC-MS/MS

    Gas Chromatography-Mass Spectrometer/MS

    ICP-MS

    Inductively Coupled Plasma-Mass Spectrometry

    TOF-MS

    Time-of-Flight Mass Spectrometry

    QTOF-MS

    Time-of-Flight Mass Spectrometry

    MS Parts

    Mass Spectrometers parts, accessories

    MS Pumps

    Consumables Product Coming Soon

    Columns

    HPLC columns | GC columns

    Sample Preparation

    Syringes | Filters | SPE catridges | QuEChERS Kits

    Vials, Plates, and Certified Containers

    Vials | Caps | Microplates | Containers

    Other Products

    Total Organic Carbon

    Dissolution Systems

    Chillers & Coolers

    Analytical Balances

    Gas Generators

    Agilent logo.
    Waters logo.
    Shimadzu logo.
    Thermo Fisher Scientific logo.
    Perkin Emler logo.
    Close-up view of advanced laboratory instrumentation with interconnected components and control systems.
    Shop all products
  • Services

    Categories

    Service Options

    Repair Service
    Qualification
    Service Contracts
    Warranty
    Installation & Training
    Maintenance
    Method Development
    Analytical Testing
    Standard Operation Procedure (SOP)
    GMP Consultation
    Sell or trade-in
    Equipment Financing

    Related Blogs

    View all
    View all services
  • Application Notes
    Cannabis

    Explore analytical methods for potency, pesticide, heavy metal, solvent, and microbial testing to ensure cannabis product safety and compliance.

    Environmental

    Find applications for analyzing air, water, soil, and waste to support environmental monitoring and regulatory standards.

    Energy

    Explore applications for analyzing biofuels, petroleum, and natural gas to support quality control and alternative fuel development.

    Cosmetic

    Learn about testing methods for beauty and essential oil products to assess quality, safety, and ingredient integrity.

    Medical

    Discover testing solutions for clinical, protein, forensic, and veterinary analysis supporting healthcare and diagnostics.

    Nutraceutical

    Access methods for evaluating herbal medicines and supplements for purity, potency, and safety assurance.

    Pharmaceutical

    Find applications for analyzing raw materials, active ingredients, and finished products to support drug safety.

    Chemical

    Review analytical approaches for inorganic, organic, and polymer materials to ensure composition accuracy and performance.

    Food & Beverage

    Explore testing applications for nutritional content, additives, and contaminants to ensure product quality and compliance.

    Mining

    Applications for analyzing ores, minerals, and geochemical samples.

    Pesticide / Insecticide

    Find methods for detecting and quantifying pesticide compounds to meet regulatory and safety standards.

    all application notes
  • Blogs
  • About
  • Product
    All LC System & Parts
    LC Systems

    High-Performance Liquid Chromatography

    IC Systems

    Ion Chromatography

    LC Components
    • Detectors
    • Autosamplers
    • Pumps
    • Degassers
    • Column Compartments
    • Fraction Collectors
    • Others

    LC-MS

    Liquid Chromatography-Mass Spectrometry

    FPLC

    Fast Protein Liquid Chromatography

    LC Parts

    • LC Columns
    • Agilent parts
    • Thermo parts
    • Waters parts
    • Shimadzu parts
    • Other
    All GC System & Parts

    GC systems

    Gas Chromatography

    microGCs​ (/ μGC)

    Micro Gas Chromatography

    Autosamplers

    HPLC, GC, MS, ICP, TOC and more

    GC-MS

    Gas Chromatography-Mass Spectrometry

    Purge and Trap

    GC Parts

    GC columns and parts

    All Spectroscopy System & Parts

    FTIR

    Fourier Transform Infrared Spectroscopy

    UV-Vis

    Ultraviolet–Visible spectrophotometry

    ICP-MS

    Inductively Coupled Plasma-Mass Spectrometry

    AAS

    Atomic Absorption Spectroscopy

    ICP

    Inductively Coupled Plasma

    Spectroscopy Accessories

    Other Spectrometer

    All MS Systems & Parts

    LC-MS or LC-MS/MS

    Liquid Chromatography-Mass Spectrometer/MS

    GC-MS or GC-MS/MS

    Gas Chromatography-Mass Spectrometer/MS

    ICP-MS

    Inductively Coupled Plasma-Mass Spectrometry

    TOF-MS

    Time-of-Flight Mass Spectrometry

    QTOF-MS

    Time-of-Flight Mass Spectrometry

    MS Parts

    Mass Spectrometers parts, accessories

    MS Pumps

    Consumables Product Coming Soon

    Columns

    HPLC columns | GC columns

    Sample Preparation

    Syringes | Filters | SPE catridges | QuEChERS Kits

    Vials, Plates, and Certified Containers

    Vials | Caps | Microplates | Containers

    Other Products

    Total Organic Carbon

    Dissolution Systems

    Chillers & Coolers

    Analytical Balances

    Gas Generators

    Agilent logo.
    Waters logo.
    Shimadzu logo.
    Thermo Fisher Scientific logo.
    Perkin Emler logo.
    Close-up view of advanced laboratory instrumentation with interconnected components and control systems.
    Shop all products
  • Services

    Categories

    Service Options

    Repair Service
    Qualification
    Service Contracts
    Warranty
    Installation & Training
    Maintenance
    Method Development
    Analytical Testing
    Standard Operation Procedure (SOP)
    GMP Consultation
    Sell or trade-in
    Equipment Financing

    Related Blogs

    View all
    View all services
  • Application Notes
    Cannabis

    Explore analytical methods for potency, pesticide, heavy metal, solvent, and microbial testing to ensure cannabis product safety and compliance.

    Environmental

    Find applications for analyzing air, water, soil, and waste to support environmental monitoring and regulatory standards.

    Energy

    Explore applications for analyzing biofuels, petroleum, and natural gas to support quality control and alternative fuel development.

    Cosmetic

    Learn about testing methods for beauty and essential oil products to assess quality, safety, and ingredient integrity.

    Medical

    Discover testing solutions for clinical, protein, forensic, and veterinary analysis supporting healthcare and diagnostics.

    Nutraceutical

    Access methods for evaluating herbal medicines and supplements for purity, potency, and safety assurance.

    Pharmaceutical

    Find applications for analyzing raw materials, active ingredients, and finished products to support drug safety.

    Chemical

    Review analytical approaches for inorganic, organic, and polymer materials to ensure composition accuracy and performance.

    Food & Beverage

    Explore testing applications for nutritional content, additives, and contaminants to ensure product quality and compliance.

    Mining

    Applications for analyzing ores, minerals, and geochemical samples.

    Pesticide / Insecticide

    Find methods for detecting and quantifying pesticide compounds to meet regulatory and safety standards.

    all application notes
  • Blogs
  • About
Contact
$2 2 Cart
“Varian CP-3800 GC with Saturn 2200 GC/MS” has been added to your cart. View cart

Crude & Petroleum Fractions

Characterization of crude oil, refined petroleum fractions, and process intermediates for composition, contaminants, and quality assurance. Analytical testing supports process optimization, product certification, and regulatory compliance.

Crude Oil

Overview

Crude oil is composed of a wide range of hydrocarbon analytes, including paraffins, olefins, naphthenes, and aromatic compounds spanning from light volatile gases (C1–C4) to heavy fractions (C30+). It also contains trace components such as sulfur- and nitrogen-containing organics, resins, and asphaltenes, which influence viscosity, density, and refining characteristics. Accurate characterization of these analytes is essential for determining crude type, refining yield, combustion behavior, and environmental impact.

Test Methods

ASTM D7169-XX

Solutions

Gas Chromatography with Flame Ionization Detection (GC-FID) is a key instrument for analyzing hydrocarbon composition in crude oil. Its high sensitivity to carbon–hydrogen bonds allows precise quantification of individual hydrocarbons across a wide dynamic range. Using non-polar capillary columns and temperature programming, GC-FID effectively separates complex mixtures into distinct hydrocarbon groups. Automated injection systems ensure reproducible sample introduction, while FID response provides accurate quantification based on carbon content. When integrated with simulated distillation or retention indexing software, GC-FID delivers detailed compositional profiles that support process optimization, blending control, and regulatory compliance in petroleum laboratories.

Featured GC-FID

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more GC-FID equipment!

View all
  • Agilent 7890A GC with Leap CTC GC PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Agilent 6890 GC with FID/ECD or NPD, Agilent G1512A Controller and Agilent 6890 Auto Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • HP 5890 II GC with Dual FIDs, Split/splitless Inlet and Purged Packed Inlet


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID and AutoSampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Autosystem XL GC with dual FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 Gas Chromatograph with 8410 Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 GC With FID and 1041 Packed Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian CP-3800 GC System with Dual FID and CTC Combi PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian Star 3400 CX GC with FID and TCD


    Item ID: For PartsIn Stock
    ViewContinue Loading Done

Light Crude Oil

Overview

Light crude oil primarily consists of low-boiling hydrocarbons—straight-chain alkanes, cycloalkanes, and aromatic compounds ranging from C5 to about C20. These lighter fractions determine the crude’s volatility, viscosity, and economic value, yielding higher proportions of gasoline, naphtha, and jet fuel. Accurate analysis of these analytes is essential to assess hydrocarbon distribution, impurity content, and chemical fingerprinting for source identification or blending optimization. Trace components such as sulfur- and nitrogen-containing organics, as well as oxygenates, also influence refining behavior and environmental emissions.

Test Methods

Learn more

Solutions

Gas Chromatography–Mass Spectrometry (GC-MS) is a powerful technique for identifying and quantifying the individual hydrocarbon species and trace compounds within light crude oil. The GC separates complex mixtures into discrete chemical components based on volatility and polarity, while the mass spectrometer provides molecular identification through fragmentation patterns and accurate mass detection. Using non-polar columns (e.g., 5% phenyl methylpolysiloxane), GC-MS can resolve n-alkanes, isoalkanes, aromatics, and light biomarkers with high sensitivity. Automated sample introduction systems ensure consistent injection, and data processing software enables compound identification via spectral libraries. GC-MS is especially valuable for characterizing volatile fractions, detecting trace sulfur or nitrogen species, and generating compositional fingerprints that support quality assurance, process control, and crude source tracking.

Featured GC-MS

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more GC-MS equipment!

View all
  • Agilent 5973N MSD with 6890N GC and 7683 Liquid Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • -12% Product on sale

    HP 5973 EI/CI MSD G1099A with 6890 Plus GC & CTC Analytics Combi PAL Autosampler


    Item ID: RefurbishedIn StockPrice:

    $25000 USD

    ViewContinue Loading Done
  • Agilent 6890N with Agilent 5975C Inert XL TAD MSD G3172A


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • HP 5971A MSD with HP 5890 II GC, suitable software and rough pump


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • HP 5972 MSD with HP 5890 II GC, HP 7673B Autosampler, Data System and Rough Pump


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Thermo Finnigan Polaris with Trace 2000 GC/MS system


    Item ID: RefurbishedSold Out
    ViewContinue Loading Done
  • Thermo Finnigan TSQ 700 GC-MS/MS


    Item ID: Pre-ownedOn Backorder
    ViewContinue Loading Done
  • Thermo Finnigan GCQ and Finnigan 9000 GC/MS


    Item ID: Pre-ownedIn Stock
    ViewContinue Loading Done
  • Thermo Finnigan Voyager GC/MS with Trace 2000 GC


    Item ID: RefurbishedOn BackorderPrice:

    $13000 USD

    ViewContinue Loading Done
  • Varian CP-3800 GC with Saturn 2200 GC/MS


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • -33% Product on sale

    Varian 450-GC with Varian 220MSD and CP 8400, GC/MS


    Item ID: RefurbishedIn StockPrice:

    $16500 USD

    ViewContinue Loading Done
  • Varian 3800GC with 1200L Triple Quadruple MS/MS


    Item ID: RefurbishedSold Out
    ViewContinue Loading Done
  • Varian 3400CX GC with Varian Saturn 3


    Item ID: Pre-ownedSold Out
    ViewContinue Loading Done
  • Shimadzu GCMS-QP2010 and GC-2010 GC-MS System with AOC-20s Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Shimadzu GCMS-QP5050A and GC-17A GC-MS System


    Item ID: Pre-ownedIn Stock
    ViewContinue Loading Done

Boiling Range Distribution of Petroleum Fractions

Overview

Petroleum fractions are complex mixtures of hydrocarbons that differ in molecular weight, volatility, and boiling point. Determining the boiling range distribution provides insight into the composition and refining potential of crude oil and its derivatives, such as naphtha, kerosene, diesel, and gas oils. By understanding the proportion of light, middle, and heavy components, refiners can optimize distillation processes, product blending, and yield prediction. Accurate analysis of these analytes also aids in quality control, process monitoring, and compliance with industry standards such as ASTM D2887 and D6352.

Test Methods

ASTM D2887

Solutions

Gas Chromatography with Flame Ionization Detection (GC-FID) is the standard technique for simulated distillation (SimDist) to determine boiling range distribution in petroleum products. The GC separates hydrocarbons based on volatility under a programmed temperature ramp, while the FID quantifies each fraction according to carbon response. Using a non-polar high-temperature capillary column, the method generates chromatograms that correlate retention time with boiling point via calibration with n-paraffin standards. Automated injection systems ensure reproducibility, and integrated software converts chromatographic data into cumulative boiling curves. GC-FID SimDist provides rapid, precise results compared to traditional distillation, enabling laboratories to evaluate product quality, track refinery efficiency, and meet ASTM or ISO regulatory requirements.

Featured GC-FID

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more GC-FID equipment!

View all
  • Agilent 7890A GC with Leap CTC GC PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Agilent 6890 GC with FID/ECD or NPD, Agilent G1512A Controller and Agilent 6890 Auto Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • HP 5890 II GC with Dual FIDs, Split/splitless Inlet and Purged Packed Inlet


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID and AutoSampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Autosystem XL GC with dual FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 Gas Chromatograph with 8410 Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 GC With FID and 1041 Packed Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian CP-3800 GC System with Dual FID and CTC Combi PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian Star 3400 CX GC with FID and TCD


    Item ID: For PartsIn Stock
    ViewContinue Loading Done

Boiling Range Distribution of Petroleum Distillate

Overview

Petroleum distillates, including naphtha, kerosene, diesel, and gas oils, are refined fractions separated by their volatility and boiling point characteristics. The boiling range distribution provides a critical measure of product composition, quality, and suitability for downstream applications such as combustion, blending, and refining optimization. Understanding the proportion of light to heavy components helps predict performance properties like flash point, viscosity, and energy content. Precise determination of boiling behavior also supports compliance with ASTM and ISO fuel quality standards and assists in process control for refinery operations.

Test Methods

ASTM D7798-13
ASTM D6352

Solutions

Gas Chromatography with Flame Ionization Detection (GC-FID) is the standard analytical method for determining the boiling range distribution of petroleum distillates through simulated distillation (SimDist). In this technique, the GC separates hydrocarbon molecules by volatility using a non-polar, high-temperature capillary column, while the FID quantifies them based on carbon response. Retention times are calibrated with n-paraffin standards to establish a temperature–boiling point correlation, producing a cumulative boiling curve that represents the distillation profile. Automated injection systems and temperature programming ensure reproducible and precise measurements, while integrated software converts chromatographic data into ASTM-compliant results (e.g., ASTM D2887, D6352). GC-FID SimDist provides rapid, accurate, and reproducible characterization of petroleum distillates—supporting refinery optimization, product specification, and regulatory quality assurance.

Featured GC-FID

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more GC-FID equipment!

View all
  • Agilent 7890A GC with Leap CTC GC PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Agilent 6890 GC with FID/ECD or NPD, Agilent G1512A Controller and Agilent 6890 Auto Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • HP 5890 II GC with Dual FIDs, Split/splitless Inlet and Purged Packed Inlet


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID and AutoSampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Autosystem XL GC with dual FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 Gas Chromatograph with 8410 Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 GC With FID and 1041 Packed Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian CP-3800 GC System with Dual FID and CTC Combi PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian Star 3400 CX GC with FID and TCD


    Item ID: For PartsIn Stock
    ViewContinue Loading Done

Boiling Range Distribution of Distillates and Oils

Overview

Distillates and lubricating base oils are refined petroleum fractions characterized by their volatility, molecular weight, and hydrocarbon composition. Determining their boiling range distribution provides essential information on product quality, refining efficiency, and suitability for downstream blending or performance applications. Distillates such as diesel, jet fuel, and gas oils typically exhibit moderate volatility, while lubricating base oils contain heavier hydrocarbons with high viscosity and thermal stability. Accurate boiling range data helps predict lubrication performance, oxidation resistance, and energy yield, ensuring product consistency and compliance with industry standards.

Test Methods

ASTM D7500-12

Solutions

Gas Chromatography with Flame Ionization Detection (GC-FID) is the preferred technique for determining boiling range distribution in distillates and lubricating base oils through simulated distillation (SimDist). The GC system separates hydrocarbon components according to volatility on a non-polar, high-temperature column, while the FID provides quantitative detection based on carbon response. Calibration with n-paraffin standards establishes a correlation between retention time and boiling temperature, generating precise distillation curves in accordance with ASTM D2887 and D6352 methods. Automated samplers and programmable temperature control ensure reproducible and high-throughput analysis. GC-FID SimDist offers a fast, reliable alternative to physical distillation, providing critical compositional and volatility data for refinery optimization, product specification, and regulatory compliance.

Featured GC-FID

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more GC-FID equipment!

View all
  • Agilent 7890A GC with Leap CTC GC PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Agilent 6890 GC with FID/ECD or NPD, Agilent G1512A Controller and Agilent 6890 Auto Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • HP 5890 II GC with Dual FIDs, Split/splitless Inlet and Purged Packed Inlet


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID and AutoSampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Autosystem XL GC with dual FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 Gas Chromatograph with 8410 Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 GC With FID and 1041 Packed Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian CP-3800 GC System with Dual FID and CTC Combi PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian Star 3400 CX GC with FID and TCD


    Item ID: For PartsIn Stock
    ViewContinue Loading Done

Boiling Point Distribution of Hydrocarbon Solvents

Overview

Hydrocarbon solvents, such as hexane, heptane, toluene, and mixed aliphatic or aromatic blends, are commonly used in coatings, cleaning, extraction, and chemical synthesis. Their performance depends strongly on volatility and compositional uniformity, both governed by the boiling point distribution. Determining this distribution allows for classification of solvent grades, control of evaporation rates, and verification of product purity. Accurate analysis ensures consistency across manufacturing batches and compliance with specifications for industrial, laboratory, and environmental applications.

Test Methods

ASTM D5399-09

Solutions

Gas Chromatography with Flame Ionization Detection (GC-FID) is the standard method for determining the boiling point distribution of hydrocarbon solvents through simulated distillation (SimDist). The GC separates solvent components by volatility on a non-polar capillary column, while the FID quantifies each fraction based on carbon response. Calibration with n-paraffin standards establishes a relationship between retention time and boiling temperature, enabling the generation of precise boiling curves in accordance with ASTM D2887 or D3710. Automated injection systems and temperature-programmed ovens ensure reproducible separations, while integrated software converts chromatographic data into detailed distillation profiles. GC-FID provides rapid, accurate, and repeatable characterization of solvent volatility—supporting quality control, formulation development, and compliance with industrial performance standards.

Featured GC-FID

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more GC-FID equipment!

View all
  • Agilent 7890A GC with Leap CTC GC PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Agilent 6890 GC with FID/ECD or NPD, Agilent G1512A Controller and Agilent 6890 Auto Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • HP 5890 II GC with Dual FIDs, Split/splitless Inlet and Purged Packed Inlet


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID and AutoSampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Clarus 500 GC with FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • PerkinElmer Autosystem XL GC with dual FID


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 Gas Chromatograph with 8410 Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian 3900 GC With FID and 1041 Packed Injector


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian CP-3800 GC System with Dual FID and CTC Combi PAL


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Varian Star 3400 CX GC with FID and TCD


    Item ID: For PartsIn Stock
    ViewContinue Loading Done

Aromatic Hydrocarbons in Middle Distillates

Overview

Middle distillates, such as kerosene, jet fuel, and diesel, contain varying proportions of aromatic hydrocarbons that significantly influence combustion properties, lubricity, and emission characteristics. The main aromatic types—mono-, di-, and tri-aromatics—affect parameters like smoke point, density, and energy content. Determining the concentration and distribution of these aromatic species is crucial for assessing fuel quality, refining efficiency, and regulatory compliance (e.g., ASTM D1319 or D6379). Accurate quantification helps ensure consistent product performance and adherence to environmental standards.

Test Methods

ASTM D6591

Solutions

High-Performance Liquid Chromatography with Refractive Index Detection (HPLC-RI) is a precise and reliable method for separating and quantifying aromatic hydrocarbon types in middle distillates. The HPLC system uses a polar-modified silica or amino column with a non-polar mobile phase to achieve separation based on aromatic ring structure and polarity differences. The refractive index detector provides a universal response suitable for compounds without strong UV absorbance, making it ideal for complex hydrocarbon mixtures. Automated injection and temperature control ensure repeatable analyses, while data processing software quantifies mono-, di-, and tri-aromatic fractions. Compared to traditional fluorescent indicator adsorption (FIA) methods, HPLC-RI offers improved resolution, reproducibility, and environmental safety—supporting refinery quality control and compliance with global fuel specifications.

Featured HPLC-RI

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more HPLC-RI equipment!

View all
  • -12% Product on sale

    HP 5973 EI/CI MSD G1099A with 6890 Plus GC & CTC Analytics Combi PAL Autosampler


    Item ID: RefurbishedIn StockPrice:

    $25000 USD

    ViewContinue Loading Done
  • Shimadzu GCMS-QP2010S and GC-2010 GC-MS System with Liquid Autosampler


    Item ID: RefurbishedSold Out
    ViewContinue Loading Done
  • Shimadzu GC-2010 Gas Chromatograph with AOC-5000A PAL Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Shimadzu AOC-20i Autoinjector & AOC-20S Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done

Benzene in Hydrocarbon Solvents

Overview

Benzene is a volatile aromatic compound often present as a trace contaminant in hydrocarbon solvents such as toluene, xylene, and hexane. Even at very low levels, benzene poses serious health and safety concerns due to its toxicity and carcinogenic nature. Monitoring benzene concentration in solvents is therefore essential for ensuring product purity, regulatory compliance, and worker safety in chemical manufacturing, laboratory, and industrial applications.

Test Methods

ASTM D6229-06

Solutions

Gas Chromatography with Flame Ionization Detection (GC-FID) is a highly sensitive and accurate technique for measuring trace levels of benzene in hydrocarbon solvents. The GC separates benzene from other components based on their volatility and interaction with the column, while the FID detects organic compounds through ionization in a hydrogen-air flame. This combination provides excellent selectivity, low detection limits, and reproducible quantification. With proper calibration and high-purity carrier gases, GC-FID offers a dependable solution for quality control and trace contaminant analysis in petroleum and chemical products.

Featured GC-FID

Discover a wide range of lab equipment from top manufacturers at SpectraLab. View all to find more GC-FID equipment!

View all
  • -12% Product on sale

    HP 5973 EI/CI MSD G1099A with 6890 Plus GC & CTC Analytics Combi PAL Autosampler


    Item ID: RefurbishedIn StockPrice:

    $25000 USD

    ViewContinue Loading Done
  • Shimadzu GCMS-QP2010S and GC-2010 GC-MS System with Liquid Autosampler


    Item ID: RefurbishedSold Out
    ViewContinue Loading Done
  • Shimadzu GC-2010 Gas Chromatograph with AOC-5000A PAL Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done
  • Shimadzu AOC-20i Autoinjector & AOC-20S Autosampler


    Item ID: RefurbishedIn Stock
    ViewContinue Loading Done

SpectraLab Scientific Inc
Established in 2003,

About Us

SpectraLab Scientific is a global leader of Refurbished analytical equipment. We specialize in reconditioning equipment, integrating the best available technologies from leading manufacturers across the industry. We are committed to quality and service, delivering strong customer satisfaction. We stock over 10,000 pre-owned lab equipment, components, and mix-and-match parts for your systems.

3-12 Months Warranty

Service contracts available

Contact Us

Bulk Discounts

Discounts on large purchases

Sales Event

Payment Plans

Financing / leasing supports

Get Approval

Sell or Trade-in

Sell or trade-in your instruments

Trade-In Now

Never Miss Our Latest News!

Stay in the loop with exclusive deals, new arrivals, event updates,
and expert tips by subscribing to our newsletter!

LinkedIn.

38 McPherson St.
Markham, ON, Canada, L3R 3V6

info@spectralabsci.com

Headquarter: +1 905-946-8066
U.S. Line: +1 716-337-6808
North America Toll Free: 1-866-777-3688
Fax: +1 905-917-3567

Product

All Product
LC systems & parts
GC systems & parts
Mass Spectrometer
Spectroscopy & Elemental Analysis

Resources

Application Notes
Ordering Guide
Refurbishment Process
FAQs
Sitemap

Service

Product Service
Lab Service
Financial Service

Company

About Us
Contact Us
Blogs

Copyright © 2026 SpectraLab Scientific Inc. All right reserved.

We care about your privacy

In order to provide you a personalized shopping experience, our site uses cookies. By continuing to use this site, you are agreeing to our cookie policy.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
Scroll to top